Bertazzoni X304PIRRO Electrical Connection, OPTION 1 - FOUR Wires connection, Personal Injury

Models: X304PIRBI X304PIRVI X304PIRX X304PIRRO X304PIRBL X304PIRCR X304PIRNE X304PIRVE X304PIRGI

1 48
Download 48 pages 58.98 Kb
Page 14
Image 14
ELECTRICAL CONNECTION

ELECTRICAL CONNECTION

The appliance shall be connected to a single phase electric line rated at 120/208Vac or 120/240Vac and 60Hz frequency.

Electric power rating:

120/208Vac: 4400 Watt or 21 A max.

120/240Vac: 5500 Watt or 24 A max.

Heating elements power rating:

Oven bake element = 2100 Watt

Oven circular element = 3300 Watt

Oven broil element = 3400 Watt

Install a suitable electric power supply receptacle connection type NEMA 14‐50R able to support a load of at least 30 A (per line) according to local code requirements. For four or three wires power supply connection system see diagram below.

FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R

THREE-WIRE CONN.RECEPTACLE NEMA 14-50R

Check your local code for which of the options below should be used in grounding the receptacle power supply connections.

OPTION 1 – FOUR Wires connection:

Connect the L1 receptacle terminal to the incoming BLACK electrical supply wire (L1‐hot wire)

Connect the L2 receptacle terminal to the incoming RED electrical supply wire (L2‐hot wire)

Connect the NEUTRAL receptacle terminal to the incoming NEUTRAL (WHITE) electrical supply wire

Connect the GROUND receptacle terminal to the incoming GROUND (GREEN) electrical supply wire

OPTION 2 - THREE-Wires connection:

Connect the L1 receptacle terminal to the incoming BLACK electrical supply wire (L1‐hot wire)

Connect the L2 receptacle terminal to the incoming RED electrical supply wire (L2‐hot wire)

Connect the NEUTRAL with the GROUND receptacle terminal to the incoming NEUTRAL (WHITE) electrical supply wire

DO NOT USE EXTENSION CORDS WITH THIS APPLIANCE AS IT MAY RESULT IN FIRE, ELECTRIC SHOCK OR OTHER type of

PERSONAL INJURY.

The appliance is equipped at the factory with an electric supply cord set 4 wires type with ring terminals (L1, L2, N, Ground) suitable for range use UL/CSA listed type SRDT/DRT 2x6AWG (L1, L2)+2x8AWG (N, G) rated 300V, 40 or 50A with fused plug type NEMA 14‐50P; cable length 1,5 m.; in case the supply cord set must be replaced, it shall be replaced with an identical set having the same technical specs and following carefully the instructions and diagrams below:

1)Disconnect appliance from electrical power supply receptacle

2)Slide out the appliance from installation place to access to back enclosure panel

3)Remove back enclosure panel by removing the 6 screws as shown below

14

Page 14
Image 14
Bertazzoni X304PIRRO, X304PIRGI Electrical Connection, OPTION 1 - FOUR Wires connection, OPTION 2 - THREE-Wires connection