Billion Electric Company TA128 user manual Own Isdn

Models: TA128

1 32
Download 32 pages 45.5 Kb
Page 32
Image 32

Billion mini USB ISDN TA128

 

Error

 

 

Possible

 

 

 

 

 

Indication

 

 

Cause

 

 

Remedy

 

 

 

 

 

 

 

 

 

 

CAPI driver is

 

The Registration key

 

 

Uninstall and then reinstall the

 

 

not loaded.

 

has been destroyed.

 

 

ISDN device.

 

 

 

 

 

 

 

 

 

 

Please input

 

The subscriber

 

 

Key in the subscriber number

 

 

your own

 

number of your own

 

 

of your ISDN line in the Own

 

 

number.

 

ISDN line has not

 

 

ISDN Number box.

 

 

 

 

been entered.

 

 

 

 

 

 

 

 

 

 

 

 

 

Cannot activate

 

The ISDN line is not

 

 

Ensure that the ISDN S0 line is

 

 

S0 interface

 

connected.

 

 

securely connected to the RJ-

 

 

(“ISDN” LED is

 

 

 

 

 

45 jack.

 

 

always OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cannot establish

 

The ISDN line may

 

 

Ensure that the ISDN S0 line is

 

 

LAPD link.

 

be malfunctioning.

 

 

in good condition.

 

 

 

 

 

 

 

 

 

 

 

Connecting fail.

 

1.

Own ISDN

 

 

1. Ensure that your ISDN

 

 

(error code =

 

 

Number is

 

 

number is correct.

 

 

 

 

incorrect.

 

 

 

 

 

xxxx)

 

 

 

 

 

 

 

 

2.

Other devices on

 

 

2. Be sure no other device is

 

 

 

 

 

 

 

 

 

 

 

the same S0 line

 

 

on the same S0 line and

 

 

 

 

 

are occupying the

 

 

occupying the B channel.

 

 

 

 

 

B channel.

 

 

 

 

 

 

 

3.

The ISDN

 

 

3. Check to see if the ISDN

 

 

 

 

 

protocol is

 

 

protocol configuration is

 

 

 

 

 

wrong.

 

 

correct.

 

 

 

 

 

 

 

 

 

 

Data transfer

 

The ISDN line is not

 

 

Check the ISDN line.

 

 

error.

 

in good condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

28