Replace Light Bulb
(Select Models)
Use only BISSELL Replacement Bulbs in your BISSELL Vacuum. 1. Unplug cleaner from electrical outlet.
Using a Phillips head screwdriver, remove the two screws as shown and lift
2. off the lens.
Determine the light bulb type of your vacuum:
3. Standard Bulb
Standard Bulb – remove the bulb from the socket by grasping bulb and
4. pulling straight out. Install the new bulb by pushing it gently into the socket until the bulb snaps into place.
Large Bulb – remove the bulb from the socket by pushing in
gently and turning it towards brush. Install the new bulb by pushing it gently into the socket and turning away from the brush.
5. Reposition lens and secure with the two screws.
Clearing Clogs
The Hose on the back of the vacuum that carries the dirt from the Powerfoot to the Dust Bag can sometimes become clogged. If you notice a change in the sound of the vacuum motor, check for clogs.
1. Unplug vacuum from electrical outlet.
Pull the Bag Door outward to open and set aside. Remove the Dust Bag to
2. check the Suction Inlet for a clog.
Grasp the Quick Reach Handle and lift up to separate from the Suction Intake
3. Opening. Release the Twist 'n Snap Hose from the vacuum by turning to the right. Straighten the hose and unclog with a long, narrow object.
4. If the clog persists, turn the vacuum OFF and unplug it. Remove the Brush Cover. Check the Air Passageway for obstructions. Remove debris from this area. Reposition Brush Cover and five screws. Tighten screws securely. Make sure end of Brush Cover is snapped into place.
Maintaining TurboBrush
Select Models Only
The TurboBrush should be checked regularly for clogs or debris wrapping around the brush roll.
1.
2. If a clog is present or debris is visible, unscrew the two screws on the back of the TurboBrush to remove the faceplate and clear any obstructions.
To clean debris from the brush roll, remove the screw located by the brush
3. roll with a Phillips head screwdriver. Lift the belt cover. Remove the brush roll from the drive belt and clean debris.
Reposition the drive belt on the brush roll. Place ends of brush roll in slots
4. on sides as shown. Reposition belt cover and secure with one screw. Reposition faceplate and secure with two screws.
Large Bulb
Standard Bulb
Suction
Inlet
Air Passageway
9