90514937 BDBN1202 1/18/07 9:14 AM Page 6

RECOMMENDED MINIMUM WIRE SIZE

FOR EXTENSION CORDS

TOTAL LENGTH OF CORD

 

 

 

 

25 FT.

50 FT.

75 FT.

100 FT.

125 FT.

150 FT.

175 FT.

7.6 M

15.2 M

22.9 M

30.5 M

38.1 M

45.7 M

53.3 M

WIRE SIZE AWG

 

 

 

 

 

18

18

16

16

14

14

12

9.Use only the supplied charger when charging your tool. The use of any other charger could damage the drill or create a hazardous condition.

10.Use only one charger when charging.

11.Do not attempt to open the charger. There are no customer serviceable parts inside. Return to any authorized Black & Decker service center.

12.DO NOT incinerate the battery packs even if they are severely damaged or completely worn out. The batteries can explode in a fire.

13.A small leakage of liquid from the battery cells may occur under extreme usage, charging or temperature conditions. This does not indicate a failure. However, if the outer seal is broken and this leakage gets on your skin:

a.Wash quickly with soap and water.

b.Neutralize with a mild acid such as lemon juice or vinegar.

c.If the battery liquid gets in your eyes, flush them with clean water for a minimum of 10 minutes and seek immediate medical attention. MEDICAL NOTE: The liquid is a 25-35% solution of potassium hydroxide.

Charging Procedure

Your charger is designed to use standard 120 volt AC, 60 Hz power. Do not use DC or any other voltage. Charge time is 60 minutes depending on battery pack type and condition.

1. Plug the charger into an appropriate outlet. NOTE: Do not charge by means of an engine generator or DC power source. Use only 1 120V AC.

2.Insert the battery pack into the charger (Figure 1). Be sure the pack is fully seated in the charger. The red (charging) light will blink continuously indicating that the charging process has started.

3. The completion of charge will be indicated by the red light remaining ON continuously. The battery pack is fully charged and may be used at this time or left in the charger.

4.Unplug charger, and remove the battery pack. Place the battery in

the tool and be certain that it is inserted fully into the tool

cavity until it “clicks” into place.2

NOTE: To remove the battery pack from the product, press down on the release button on the back of the battery (Figure 2) and pull out.

Replace Pack

The charger is designed to detect certain problems that can arise with

battery packs which would be indicated by the red light flashing at a fast rate. If this occurs, re-insert battery pack. If problem persists, try a different battery pack to determine if the charger is OK. If the new pack charges correctly, then the original pack is defective and should be returned to a service center for recycling. If the new battery pack gives the same trouble indication as the original, have charger tested at an authorized service center.

Wall Mounting (Figure 2A)

A hole is provided in the center of the charger for mounting on a vertical surface.

2A

6

Page 6
Image 6
Black & Decker BDBN1202, BDBN1802, 90514937 instruction manual Charging Procedure, Replace Pack, Wall Mounting a