Black Box ACU5011A, ACU5010A manual Transmitter’s DIP-switch settings

Models: ACU5010A ACU5011A

1 64
Download 64 pages 27.8 Kb
Page 30
Image 30

CHAPTER 4: Configuration

Position 3: If you’ve password-protected the Extender’s receiver and lost the password, move this switch position to ON to put the Extender in configuration mode when it powers up. This will allow you to reset the password, as described in Section 4.4.

Position 4: To reset the Extender without removing power from the receiver or transmitter or disconnecting any of the attached devices, move this switch position to ON, then back to OFF.

Top of transmitter

Bottom of transmitter

Position 4 OFF:

Normal operation (default)

Position 4 ON, then back OFF:

Reset transmitter

Position 3 OFF:

Normal operation (default)

Position 3 ON:

Configuration mode at startup

ON

OFF

Position 1 OFF:

Normal operation (default)

Position 1 ON:

Upgrade mode for transmitter

Position 2 OFF:

Normal operation (default)

Position 2 ON:

Transparent operation

Figure 4-2. The transmitter’s DIP-switch settings.