SERVSWITCH™ WIZARD EXTENDER
Problem:
Compaq MX11800 model integrated keyboard and mouse only: The mouse consistently fails to boot when the Extender is connected to a PC running Windows NT® 4.0 through its PS/2 style mouse port.
Possible Solutions:
There are three possible solutions to this problem:
1.Use a different type of mouse.
2.Connect the Extender to your NT 4.0 PCs through an adapter and one of the PC’s serial ports rather than through its PS/2 port.
3.Select “CPU zero” while NT is booting. You should be able to use the system normally once the logon screen appears.
7.4Resetting the Extender (Hardware Reset)
The ServSwitch Wizard Extender has a
7.5 Displaying the Extender’s Firmware Revision
For
1.Go into configuration mode by pressing the hotkeys followed by [Enter] at the primary control station’s keyboard.
2.Get the Extender to report its firmware revision by issuing the [F] [1] [Enter] command. (“[F] [1]” is the letter “F” followed by the number “1”, not the [F1] function key.)
3.Press [Enter] again to exit configuration mode.
The version number will be reported on screen as the letter “V” followed by three numbers, the first of which is the major revision level and the other two of which are the minor revision level. For example, if the Extender reports “V118”, the firmware version is 1.18.
54