Table 5-1 (continued). Performance Data.

Chapter 5: Performance, Electrical, and Sound Data

Table 5-1 (continued). Performance Data.

 

 

 

Total Capacity

Sensible Capacity

Flow Rate

Total System

 

 

12" Chilled Water

Temperature

Pressure Drop

 

 

 

 

 

 

 

 

 

(CRCW-12)

Change

 

 

 

 

 

 

 

 

BTU/H

kW

BTU/H

kW

GPM

(ft. H2O)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80° F DB/64.5° F WB Entering AIr Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

81,155

23.8

77,151

22.6

16.6

9.0

 

 

 

change

 

 

40° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

72,250

21.2

72,250

21.2

12.3

6.0

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

61,703

18.1

61,703

18.1

12.6

6.2

 

 

 

change

 

 

45° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

56,587

16.6

56,587

16.6

9.7

4.5

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

49,488

14.5

49,488

14.5

10.2

4.8

 

 

 

change

 

 

50° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

44,393

13.0

33,393

13.0

7.7

3.7

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Capacity

Sensible Capacity

Flow Rate

Total System

 

 

24" Chilled Water

Temperature

Pressure Drop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CRCW-24)

Change

BTU/H

kW

BTU/H

kW

GPM

(ft. H2O)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100° F DB/69.2° F WB Entering AIr Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

263,192

77.1

250,429

73.3

54.5

39.4

 

 

 

change

 

 

40° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

251,539

73.7

245,539

71.9

43.5

26.8

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

219,854

64.4

219,854

64.4

45.9

29.2

 

 

 

change

 

 

45° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

211,927

62.1

211,927

62.1

37.0

20.2

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

192,259

56.3

192,259

56.3

40.5

23.4

 

 

 

change

 

 

50° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

186,556

54.6

186,556

54.6

32.8

16.5

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

95° F DB/67.7° F WB Entering AIr Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

242,729

71.1

227,717

66.7

50.5

34.8

 

 

 

change

 

 

40° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

230,726

67.6

222,663

65.2

40.1

23.3

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

199,089

58.3

199,089

58.3

41.8

24.9

 

 

 

change

 

 

45° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

190,287

55.7

190,287

55.7

33.4

17.0

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10° F Temperature

170,772

50.0

170,772

50.0

36.2

19.4

 

 

 

change

 

 

50° F EWT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12° F Temperature

164,228

48.1

164,228

48.1

29.0

13.4

 

 

 

 

 

 

change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 