Black Box IC266A manual Configuration, Electrical Interface Selection

Models: IC266A

1 26
Download 26 pages 23.05 Kb
Page 15
Image 15
4.Configuration

USB SINGLE-PORT HUB (RS-422/485)

4.Configuration

4.1Electrical Interface Selection

The port on the USB Single-Port Hub (RS-422/485) can be used as RS-530/422/485, RS-422, or 2-wire RS-485. This is selectable via the DIP-switch SW1. The chart below describes each of the positions’ functions. Please refer to the next page for switch setting examples. Switch SW1 ON enables, adds, and connects. SW1 position OFF disables, removes, and disconnects.

SW1

Function

 

 

1

RS-485 two-wire auto enable/disable (ON=Enable).

 

 

2

Echo enable/disable (ON=Disable).

 

 

3

Adds or removes the 120-ohm termination.

 

 

4

Adds or removes the 1 Kohm pull-up resistor in the

 

RS-422/RS-485 receiver circuit (Receive data only).

 

 

5

Adds or removes the 1 Kohm pull-down resistor in the

 

RS-422/RS-485 receiver circuit (Receive data only).

 

 

6

Connects TX+ to RX+ for RS-485 two-wire operation.

 

 

7

Connects TX- to RX- for RS-485 two-wire operation.

 

 

8

Not used.

 

 

 

 

14

Page 15
Image 15