BLADEOS 6.3 Application Guide

3.Boot the switch and access the Boot Management menu by pressing <Shift B> while the Memory Test is in progress and the dots are being displayed.

4.Select 3 for Xmodem download. When you see the following message, change the Serial Port characteristics to 115200 bps:

##Switch baudrate to 115200 bps and press ENTER ...

5.Press <Enter> to set the system into download accept mode. When the readiness meter displays (a series of “C” characters), start XModem on your terminal emulator.

6.Select the Boot Image to download. The XModem initiates the file transfer. When the download is complete, a message similar to the following is displayed:

yzModem - CRC mode, 62494(SOH)/0(STX)/0(CAN) packets, 6 retries

Extracting images ... Do *NOT* power cycle the switch.

**** VMLINUX ****

 

Un-Protected 10 sectors

 

Erasing Flash

done

Writing to Flash

done

Protected 10 sectors

 

**** RAMDISK ****

 

Un-Protected 44 sectors

 

Erasing Flash

done

Writing to Flash

done

Protected 44 sectors

 

**** BOOT CODE ****

 

Un-Protected 8 sectors

 

Erasing Flash

done

Writing to Flash

done

Protected 8 sectors

 

BMD00178, April 2010

11

Page 11
Image 11
Blade ICE BMD00178 manual ## Switch baudrate to 115200 bps and press Enter