INFRARED/RADIANT COMPACT BROILER | CLEANING & MAINTENANCE |
CLEANING & MAINTENANCE
WARNING
Shut off the gas supply to the appliance before cleaning or performing maintenance on any gas appliance.
The appliance may be equipped with a restraint device to limit its movement in order to prevent damage to the gas connection. If disconnection of this restraint is necessary to move the appliance for cleaning or maintenance, reconnect the restraint when the appliance is moved back to its original installed position.
Blodgett Range equipment is sturdily constructed of the best materials and is designed to provide durable service when treated with ordinary care. To provide the best performance, your equipment must be maintained in good condition and cleaned daily. Naturally, the periods for this care and cleaning depend on the amount and degree of usage.
Following daily and periodic maintenance procedures will enhance long life for your equipment. Climatic conditions (such as salt air) may require more thorough and frequent cleaning or the life of the equipment could be adversely affected.
Keep exposed, cleanable areas of broiler clean at all times. (See next page for instructions on cleaning stainless steel and
DAILY CLEANING AND MAINTENANCE
To prevent excess smoking, the broiler grid, bottom grease drawer, and the other broiler components must be kept clean of food remnants. Use a wire brush or similar scraping utensil. DO NOT use steel wool or a similar scrub pad that will leave small particles, which can get into food. The daily cleaning procedure is as follows:
1.Move the broiling rack to the low position. Pull out the rolling broiler rack.
2.Lift out the broiler grids and clean them with a wire brush or
3.Lift out the (2) drip shields and clean them with soap and water.
4.With rolling rack
5.Remove the bottom grease drawer and clean it.
6.Clean all parts of the raising and lowering frame.
7.Lubricate bearings with cooking oil (helps to extend the life of the bearings).
8.Reassemble broiling rack mechanism.
9.Check that nothing has been placed on top of the broiler (which will block the escape of combustion exhaust).
10.Check that the
MONTHLY CLEANING AND MAINTENANCE
The following tasks should be performed monthly:
1.Check for proper pilot operation. The flame on each pilot should be just large enough to extend along the flame carrier to the burner surface. If adjustment is necessary, call for service.
2.Infrared: Check for proper burner operation. When the burner control is set to HIGH, the ceramics should glow red and the flame on the surface of the ceramics should be barely visible, with little or no blue haze. When the burner control is set to LOW, the surface of the ceramics should glow very dull red and the flame should have a
Radiant: Check for proper burner operation. When burner control is set to HIGH, blue flames should emit from the tube burner, and spread over the stainless steel radiant causing the radiant to glow.
SEMIANNUAL CLEANING AND MAINTENANCE
At least twice a year the venting system should be examined and cleaned.
INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06) | PAGE 11 OF 24 |