Blodgett B36-RAD, B48-RAD, B48-NFR manual Mounting of Infrared/Radianr Compact Broiler on Flue-Riser

Models: B36-NFR B36-RAD B48-NFR B48-RAD

1 24
Download 24 pages 60.73 Kb
Page 14
Image 14
STEP 2A: MOUNT ON FLUE RISER OF RANGE

INSTALLATION

INFRARED/RADIANT COMPACT BROILER

STEP 2A: MOUNT ON FLUE RISER OF RANGE

The Infrared/Radiant Compact Broiler mounts over a range. A special flue riser is shipped with the broiler and range. Depending on the shipping requirements, the broiler, flue-riser, and range base may already be partially or completely assembled.

1.Attach the flue riser to the rear of the range using the installation procedure included in the range manual, but do not attach the wall shield (the back of the flue riser) yet.

2.Lift the broiler (using two people is recommended) and hook the broiler-hook over the top-front edge of the flue riser. If necessary, move the broiler left or right so that the holes in the top of the broiler hook line-up with the holes in the top of the flue riser, then secure the broiler-hook to the flue riser using three #10 self tapping screws - provided.

3.Secure the bottom of the broiler to the flue riser with the four ¼” self-tapping screws provided. The holes are accessible from the rear of the unit behind the wall shield.

4.If the optional internal piping from the broiler to the range was ordered, connect the gas line now (as described in Step 3), before attaching the wall shield.

5.Attach the wall shield, which forms the rear of the flue riser. The gas supply inlet extending out from the rear of the broiler should be accessible through the corresponding hole on the back of the flue riser.

6.Go on to Step 3.

Figure 4

Mounting of Infrared/Radianr Compact Broiler on Flue-Riser

PAGE 14 OF 24

INSTALLATION & OPERATIONS MANUAL 1186529 REV 3 (12/06)

Page 14
Image 14
Blodgett B36-RAD, B48-RAD manual Mounting of Infrared/Radianr Compact Broiler on Flue-Riser, A Mount On Flue Riser Of Range