ENGLISH
IV. ELECTRICAL SUPPLY
WARNING
Authorized supplier personnel normally accomplish the connections for the ventilation system, electric supply, and gas supply, as arranged by the customer. Following these connections, the
NOTE: The electric supply installation must satisfy the requirements of the appropriate statutory authority, such as the National Electrical Code (NEC), ANSI/NFPA70, (U.S.A.); the Canadian Electrical Code, CSA C22.2; the Australian Code, AG601; current IEC/CEE requirements (CE countries); or other applicable regulations.
NOTE: All aspects of the electrical supply connection must comply with all applicable local, national, and international code requirements.
Check the oven serial plate before making any electric supply connections. Electric supply connections must agree with data on the oven serial plate. The location of the serial plate is shown in Figure
A fused disconnect switch or a main circuit breaker (customer furnished) MUST be installed in the electric supply line for each oven cavity. It is recommended that this circuit breaker/disconnect have lockout/tagout capability. For CE installations, the circuit breaker/disconnect must have a minimum of 3mm contact separation breaking all poles of the supply.
The supply conductors must comply with all applicable local, national and international codes. Supply conductors must be insulated copper wiring, #18 AWG (American Wire Gauge) or equivalent. Additional wiring information is shown on the wiring diagrams in Section 5, Electrical Wiring Diagrams and inside the machinery compartment of the oven.
SECTION 2 - INSTALLATION
The oven requires a ground connection to the oven ground screw located in the electrical junction box. (The box is shown in Figure
A.Additional Information - Gas Ovens
All electric supply connections are made via the electrical junction box on the rear of the oven, shown in Figure
•When the Control Compartment Access Panel is opened;
•When the Machinery Compartment Access Panel is opened,
OR
•When the rear panel is removed.
B.Connection
Refer to the wiring diagram inside the machinery compartment, or in Section 5 of this Manual, to determine the correct connections for the electrical supply lines. Connect the supply as indicated on the wiring diagram.
If required by local, national or international codes, connect an
equipotential ground wire to the lug next to the symbol (shown in Figure
must meet all applicable national and local code requirements.
Figure 2-15 - Utility connection locations
33mm cutout for
electric utility
connection
| 1/2" NPT pipe for gas | |
Equipotential | utility connection | |
(fitted with 3/4" adapter | ||
ground lug | ||
for use with supplied | ||
| ||
| 3/4" dia. gas hose) |
Electrical
Junction Box
12