Installation
19
Final Check Lists
WARNING!!
Final check list must be performed by a
qualified installer only.
ELECTRICAL CONTROL COMPARTMENT
jVoltage to appliance matches rating plate
PLUMBING FINAL CHECK
jIncoming water pressure within appliance
specification.
jAtmospheric vented drain in place.
jWater feed lines intact without leaks.
jEnsure proper clearance as detailed on page
8.
jDelime system has been primed. BCXĆ14 only.
OVEN OPERATIONAL TESTS
NOTE: Checks to be made by customer or authoĆ
rized service agent.
Cool Down Mode
jCheck that the fan runs with the door open.
Steam Mode - BCXĆ14 and BXĆ14 only
Turn on STEAM mode and set thermostat to
steam. Verify the following:
jHeat demand lamp is on.
jHeat demand lamp shuts off at approximately
212_F (100_C).
jSet timer for 1 minute by pressing the key.
Press to count down. Be sure the buzzer
sounds when the time expires.
jRun light (power light) turns on.
jUnit produces steam, window fogs, door seal
does not leak.
Combi Mode - BCXĆ14 and BXĆ14 only
Turn to COMBI mode, set thermostat to 350_F
(177_C) and verify:
jHeat demand lamp is on.
jOven is heating.
jHeat demand lamp shuts off at 350_F (177_C)
and oven maintains 350_F (177_C).
jFan shuts off with door open.
Hot Air Mode - All models
Turn to HOT AIR mode and set thermostat to
400_F (204_C) and verify:
jHeat demand lamp is on.
jOven is heating.
jHeat demand lamp shuts off at 400_F (204_C)
and oven maintains 400_F (204_C).
jFan shuts off with door open.
Steam On Demand Mode - BCXĆ14 and BXĆ14
only
Turn the oven to Hot Air mode. Set Steam On DeĆ
mand for 1 minute. Press the Steam On Demand
button and verify:
jSteam demand lamp is on.
jSteam demand lamp shuts off after approxiĆ
mately 1 minute.
Lights
jRotate switch to ensure lights come on.
Cavity Vent
jRotate switch to ensure that the vent opens
and closes.
Fan Speed
jRotate switch to ensure all fan speeds work.