Blodgett SB-10E, SB-6E, SB-16E manual OPERATING INSTRUCTIONS Continued, Shut Down

Models: SB-10E SB-16E SB-6E

1 14
Download 14 pages 59.78 Kb
Page 8
Image 8

3.0 OPERATING INSTRUCTIONS (Continued)

High Pressure Condition, CSD-1 Controls

A high pressure safety switch is installed on the boiler. Should the pressure exceed the limit of this device, the boiler will be shut down and switch to a state of lockout. The “Pressure” pilot light (red), and the “Standby” pilot (amber), will come on. Should this device fail to operate, the safety relief valve will open.

Low Water Condition, Standard Controls

A low water safety cut off is supplied with the boiler. Should the water level fall below normal operating levels, the boiler will shut down. If the water level is returned to a safe level, normal boiler operation will resume.

Low Water Condition, CSD-1 Controls

A second low water safety cut off is supplied with the boiler. Should the water level fall below normal operating levels, the boiler will shut down and switch to a state of lockout. The “Low Water” pilot light (red), and the “Standby” pilot (amber) will come on.

SHUT DOWN

Turn off power switch, open manual drain valve. If unit is equipped with automatic blowdown valve, it will open and drain the boiler.

8

Page 8
Image 8
Blodgett SB-10E, SB-6E, SB-16E manual OPERATING INSTRUCTIONS Continued, Shut Down