4.0PERIODIC MAINTENANCE

4.0PERIODIC MAINTENANCE

Never spray water into electric controls.

NOTICE: Contact the factory, the factory representative or local service company to perform maintenance and repairs. Refer to warranty terms.

Be sure to flush your boiler water level control daily. Failure to follow this procedure can cause the control to malfunction resulting in serious boiler damage.

The Boiler Water Level Control installed on your boiler requires periodic maintenance. As boiler water circulates into the float chamber, sand, scale and other sediment may be deposited in the float chamber. While the chamber has been designed with a large accumulation bowl, it is necessary to flush the sediment from the chamber by blowing down the control so that the accumulation of sediment does not interfere with the movement of the float in the control. Control must be flushed at least once a day.

CAUTION: Scald Hazard. Protect yourself. When flushing control, hot water and steam will flow out of the drain.

CAUTION: Disconnect the power supply during cleaning or servicing.