24.6 ” (625 mm) min.

900900

 

22.05

560

mm

.

 

min

36.14”

(918 mm)

min.

( 23½" 595 mm)

21¼" mm) (540

33½"

(850 mm)

Minimum Installation

Clearances

 

Alcove or

Closet

 

Built-under

 

 

 

 

Sides

0.59 in. (15 mm)

0.59 in. (15 mm)

 

 

 

Top

2.68 in. (68 mm)

2.68 in. (68 mm)

 

 

 

Rear

0.59 in. (15 mm)

0.59 in. (15 mm)

 

 

 

Front

0.20 in. (5 mm)

0.20 in. (5 mm)

 

 

 

Ventilation Requirements

Closet door must have 2 openings, one located 3.2 inches (8 cm) from bottom of door having a minimum area of 16 sq. inches (103 cm2) and the other one located 3 inches (7.5 cm) from top of door having a minimum area of 46 sq. inches (294 cm2).

Use on top of a washing machine

•A stacking-kit (Part no: 296 710 0100) should be used between the two machines for use on top of a washing machine. The stacking-kit should be installed by the Authorized Service provider.

•Place the appliance on a solid floor. If it is to

10 - EN