be placed on top of a washing machine, the approximate weight together may reach 397 lbs (180 kg) when they are full. Therefore, the floor must be capable of carrying the load placed on it!

To connect a ventilation duct; 1.Connect the air outlet metal duct to the spacer by turning it counter-clockwise. 2.Make the duct passages as shown the picture below.

Adjusting the feet

In order to ensure that your appliance operates more

silently and vibration-free,

it must stand level and balanced on its feet. The

front feet of the appliance can be adjusted. Balance the appliance by adjusting the feet.

1.Loosen the feet by hand.

2.Adjust them until the appliance stands level and firmly.

CDo not use any tools to loosen the adjustable feet. Otherwise, they may be damaged.

CNever unscrew the adjustable feet from their housings.

2plastic pieces supplied together with the Operating Instructions prevent your appliance from slipping on wet and slippery surfaces. To install these plastic parts:

1.Tilt the appliance backwards.

2.Fit the plastic parts to the front adjustable feet. Press on the plastic parts to fix them in their places.

3.Check the balance of the appliance again and readjust the adjustable feet if necessary.

Ventilation duct and connection

Ventilation duct ensures exhaust of air from inside the appliance.

The vented dryer has 1 air outlet.

AOnly rigid or flexible metal duct should be used for exhausting, unless the appliance has been checked for use with nonmetallic duct or the duct has been checked and found acceptable for use with clothes dryers.

In Canada, the diameter of the duct to be used should be 4” (102 mm). In United States, the regulation for the required exhaust duct diameter must be followed.

Maximum duct length is given in the table below:

Metal rigid duct

Maximum length 21 ft (6.5 m) + 2 elbows

CExhaust of humid air from the dryer into the room is to be avoided. It may damage the walls and furniture in the room.

CThe ventilation duct can be routed outdoors via a window or it can be connected to the air outlet in a bathroom.

CAir outlet duct must be extended directly outdoors. There must be a limited number of

11 - EN

Page 11
Image 11
Blomberg DV 17542, DV 17540 NBL00 Adjusting the feet, Ventilation duct and connection, Silently and vibration-free