7Recommended solutions for the problems

Please review this list before calling the service. It might save you time and money. This list includes frequent complaints that are not arising from defective workmanship or material usage. Some of the features described here may not exist in your product.

The refrigerator does not operate.

Is the refrigerator properly plugged in? Insert the plug to the wall socket.

Is the fuse of the socket which your refrigerator is connected to or the main fuse blown out? Check the fuse.

Condensation on the side wall of the fridge compartment (MULTIZONE, COOL CONTROL and FLEXI ZONE).

Very cold ambient conditions. Frequent opening and closing of the door. Highly humid ambient conditions. Storage of food containing liquid in open containers.

Leaving the door ajar. Switching the thermostat to a colder degree.

Decreasing the time the door left open or using it less frequently.

Covering the food stored in open containers with a suitable material.

Wipe the condensation using a dry cloth and check if it persists.

Compressor is not running

Protective thermic of the compressor will blow out during sudden power failures or plug-out plug-ins as the refrigerant pressure in the cooling system of the refrigerator has not been balanced yet. Your refrigerator will start running approximately after 6 minutes. Please call the service if the refrigerator does not startup at the end of this period.

The fridge is in defrost cycle. This is normal for a full-automatically defrosting refrigerator. Defrosting cycle occurs periodically.

Your refrigerator is not plugged into the socket. Make sure that the plug is properly fit into the socket.

Are the temperature adjustments correctly made?

Power might be cut off.

26

EN

Page 27
Image 27
Blomberg KFD 9952 X, KFD 9950 X manual Recommended solutions for the problems