OPERATION (continued)
12.View Filter Statistics: To view filter statistics, turn the brewer off. Press and hold the 1st key (Brew), and depress the 3rd (ON/OFF) key. Total water volume will be displayed (TotalVol.). Press the 3rd key to view the Filter Life (FltrLife:). Press the 3rd key to view the percentage of the filter that has been used. (If the filter option is used, the filter life volume needs to be entered in the program – see
13.Diagnostic Messages – Programmed Safety Features: When E-Max T™ senses a problem, it will automatically turn off all elements and valves, flash lights, display the message
“Call For Service” and display one of the messages below. (Additionally: a service phone number may appear if it has been programmed into the system.)
*To reset the brewer it can be
A.“Probe/Heater Error”: Overheating Detection (1): If the heating element is on for 5 minutes and the temperature does not change by +2°F (1°C) in the five minute period, the unit will go into the Over Temperature Mode with all lights flashing. When in this mode the brewer turns off the heating elements, the solenoid valves are turned off; the switches disabled; (and all lights flashing continuously). The LCD display will read “Probe/Heater Error”, followed by the message “Call for Service”, and then the service phone number (if it has been entered into memory). To reset press and hold CANCEL for 3 seconds, or
B.“Overheat Error”: Overheating Detection (2): If the
C.“No Water Sensed” —
D.“No Water Sensed” —
60 seconds without water being detected at the proper level, the brewer will go into the same error mode as above (“no water sensed”). To reset press and hold CANCEL for 3 seconds, or
E.Keyswitch Locked: If a key switch is depressed for 10 seconds this error message will occur. Lights will flash alternately and the brewer will turn off all valves and elements. Press and hold the CANCEL key for 3 seconds to reset the brewer (or
F.“Valve Fault”- Faulty Valve Detection: When an electric or switching problem is detected with either the inlet or brew valve the brewer turns off all elements and valves and displays “valve fault…”. All of the lights will be turned on. Before