OPERATION

To over-ride the Brew Wait mode, press and hold the BREW key for 3 seconds when the brewer is in Brew Wait mode (i.e. when brew light is flashing). The brew will proceed immediately regardless of water temperature. This feature should only be used when testing water volume, otherwise the brew will proceed with the water below the precise brew temperature.

Note: the following safety features have been incorporated to prevent multiple unattended brews:

The brew key is in- operative during a brew cycle. This minimizes the possibility of double brewing.

When the “Brew” light is on or flashing, repeated pressing of the BREW switch will be ignored, (there will be a beep each time it is pressed). A Brew will only be activated when the “Brew” light is off.

OPERATING INSTRUCTIONS

1.Energizing the Brewer: When electricity has been connected to the unit, there will be a momentary flash of the power light. Turn

the brewer on by pressing the POWER key. The brewer will start to fill the tank. With the proper water supply the tank should be filled in about 2½ minutes. Once filled, the heating element will come on until the proper tank temperature has been reached, (which will take about 20 minutes on 120-Volt models or about 12 minutes on 120/240 Volt models).

2.Brewing (Precise Temperature for Brewing™ — PTB™): In the regular operating mode, the E-Max™ LX maintains the tank

temperature within +/- 1ºF of the brew

temperature. Normally this will mean that a

brew will be started as soon as the BREW key

OPERATING INSTRUCTIONS is pressed. However, there may be a slight delay if the BREW key is pressed immediately after a brew has been completed (notably on 120-volt models). If the tank temperature is below the brew temperature, the brew will be delayed, going into the “Brew Wait” mode, with the brew light flashing. As soon as the correct

temperature is reached the brew will commence with the brew light on continuously during the brew. When the brew begins the main warming station will be turned on automatically (if it is not already on). During the brew cycle, if the BREW key is pressed, it will be ignored. Only when the brew is complete can another brew be started.

3.Brew Cancel: To cancel a brew in progress, press the CANCEL KEY: two beeps will sound and the “Brew” light will go out. Water flowing to the brew chamber

Manual background will be stopped immediately, but if there is Manual background already water in the brew chamber, it will take a few moments before this drips through as coffee.

4.Normal Operation (Non Brewing): When the unit is not brewing, the E-Max™ LX maintains the water temperature at the Precise Temperature for Brewing™ (PTB™). The heating element will cycle on and off automatically to maintain this temperature.

5.After Hours Mode: If no brew is detected for a pre-selected length of time, the brewer will enter the After Hours mode. Temperature will be allowed to drop to save energy. Pressing the BREW KEY returns the brewer to normal operation.

6