SERVICING INSTRUCTIONS (continued)

REPLACE HEATING ELEMENT

IMPORTANT: When replacing

Remove tank lid assembly per above.

heating element, also replace

seal gaskets.

 

Remove two hex nuts holding element to cover. Pull element from mounting holes.

Reassemble in reverse order.

REPLACE SOLENOID

Symptom: brewer will not flow water; or, brewer drips continuously from brew head.)

Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting.

Remove water bottle and top panel.

Cut tie straps from solenoid hose connections. Remove wiring connections from solenoid coil. Remove solenoid

Reassemble in reverse order.

REPLACE TIMER ASSEMBLY

Unplug power cord or turn circuit breaker OFF.

Remove front panel. Remove knob and three screws holding timer to bracket. Disconnect wiring to timer.

Reassemble in reverse order.

Adjust timer as described on page 12.

REPLACE BREW READY LIGHT OR BREW SWITCH

Unplug power cord or turn circuit breaker OFF. Remove water bottle, top panel and basin pan.

Using Switch Removal Tool (p/n 83209) or a thin screwdriver, pry light or switch from mounting hole. Disconnect leads.

Reassemble in reverse order.

13

Page 15
Image 15
Bloomfield 8382 Replace Heating Element, Replace Solenoid, Replace Timer Assembly, Replace Brew Ready Light or Brew Switch