IMPORTANT: Adjust timer with a full water bottle installed in the bottle ring.
IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid.
DO NOT OVER-TIGHTEN.
IMPORTANT: When removing tank lid assembly, be careful to not damage or kink thermostat capillary tube.
IMPORTANT: When mounting thermostat, be sure a new seal washer is placed below the fitting on the capillary line. Push sensing bulb thru tank lid until fitting seats.
Tighten capillary lock nut only enough to ensure no water leakage. Excessive tightening is not necessary.
SERVICING INSTRUCTIONS (continued)
TIMER ADJUSTMENT
The amount of water dispensed automatically during a brew cycle is controlled by the timer.
Place empty airpot under brew chamber. Press BREW button. Brewer should dispense one airpot of water. To adjust amount:
Remove brew chamber and button plug. Adjust knob on timer; clockwise increases time. Run several cycles to check amount of water delivered. Replace button plug.
REMOVE TANK LID ASSEMBLY
Unplug brewer or turn circuit breaker OFF. Remove water bottle. Run water from the hot water faucet until no more water flows Remove top panel. Siphon water from the tank through the faucet supply fitting until the water level in the tank is below the tank lid.
Pull vent tube and inlet elbow out of basin pan. Remove basin pan.
Disconnect faucet supply from tank lid.
Disconnect wires from thermostat. Remove screws holding thermostat to bracket. Do not remove thermobulb from tank lid.
Disconnect all wiring from heating element. Slide
Loosen center screw on tank
Reassemble in reverse order.
REPLACE THERMOSTAT
Unplug brewer or turn circuit breaker OFF. Remove water bottle and drain water from hot water faucet until no more water flows. Remove top panel.
Disconnect all wiring from thermostat only. Loosen and free jam nut from
Lift out thermostat, sensing bulb and thermostat gasket. Reassemble in reverse order.
12