Bloomfield 8572, 8540, 8541, 8542, 8573, 8543, 8571 Servicing Instructions, Temperature Adjustment

Models: 8574 8572 8571 8543 8573 8542 8541 8540

1 28
Download 28 pages 49.8 Kb
Page 14
Image 14

SERVICING INSTRUCTIONS (continued)

CAUTION

Electric Shock

Hazard

These procedures involve exposed electrical circuits. These procedures are to be performed by qualified technical personnel only.

TEMPERATURE ADJUSTMENT

Unplug power cord or turn circuit breaker OFF. Remove top panel.

Pull vent tube out of tank lid and insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power.

THERMOSTAT

DIAL-TYPE

THERMOMETER

ADJUSTING

IN VENT HOLE

SHAFT

 

TANK LID

 

ASSEMBLY

 

NOTE:

Optimum brewing temperature range is 195ºF to 205ºF (90ºC to 96ºC).

IMPORTANT:

A mechanical thermostat will

maintain temperature within

±10ºF. To prevent boiling water

in the brewer, thermostat should

Fig. 10 Checking and Adjusting Brew Temperature

Place an empty decanter under brew chamber. Energize brewer and pour one decanter (64 oz.) of cold water into pour-over opening. When READY TO BREW light comes on, read temperature displayed on thermometer.

Adjust thermostat by turning shaft; clockwise increases temperature. 1/8 turn = approximately 10ºF.

Refer to Table 1 below for proper brewing temperature based on altitude.

be adjusted to a maximum

temperature equal to the local

boiling temperature minus 10ºF.

TEMP. (ºF)

210

205

200

195

190

0

500

1,000

1,500 2,000

2,500

3

3,500

0

4,500

5

5,500 6,0

6

 

4,00

 

 

 

 

,000

 

 

 

,000

 

00 ,500

ELEVATION (feet above seal level)

BOILING

POINT OF WATER

IDEAL BREWING TEMPERATURE

MAXIMUM SAFE TEMPERATURE SETTING

Table 1 Boiling Temperature by Altitude

Upon completion, remove thermometer and reinstall vent tube.