Bloomfield 8742 owner manual Water Line Strainer, Replace Heating Element, Replace Solenoid

Models: 8742

1 22
Download 22 pages 27.14 Kb
Page 16
Image 16
Fig. 12 Water Line Strainer

SERVICING INSTRUCTIONS (continued)

IMPORTANT: When replacing heating element, also replace seal gaskets.

Fig. 12 Water Line Strainer

REPLACE HEATING ELEMENT

Remove tank cover assembly (see page 13).

Remove two hex nuts holding element to cover. Pull element from mounting holes.

Reassemble in reverse order.

REPLACE SOLENOID

Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head.

Unplug power cord or turn circuit breaker OFF. Turn water supply OFF.

Remove top panel.

Disconnect wiring from solenoid. Unscrew water inlet piping from solenoid. Remove two screws holding solenoid to bracket.

Remove brew and dilution manifold from solenoid, transfer components to new solenoid

Transfer solenoid bracket to new solenoid. Reassemble in reverse order.

REPLACE TIMER ASSEMBLY

Unplug power cord or turn circuit breaker OFF.

Remove top panel. Remove knob and three screws holding timer to bracket. Disconnect wiring to timer.

Reassemble in reverse order.

Adjust timer as described on page 13

CLEAN STRAINER SCREEN

Unplug power cord or turn circuit breaker OFF. Turn water supply OFF.

Remove bottom cap from strainer. Withdraw filter screen from strainer body.

Clean screen with a suitable brush. Reassemble in reverse order.

606 Owners Manual for 8742-8748 Tea Brewer 76116