SERVICING INSTRUCTIONS (continued)

10.Reinstall tank lid assembly into hot water tank. Make sure the lid gasket is properly in place, then reinstall the hold- down clamps.

11.Remove spray disks and gaskets. Rinse both brew heads with clean water. Using a stiff brush, scrub spray disk to remove any lime or calcium build-up. Reinstall gaskets and spray disks.

13.Reconnect brewer to electrical supply .

14.Install the brew chamber without filter paper or grounds.

15.Place an empty satellite under the brew chamber. Run at least five 1-1/2 gallon brew cycles and discard all water generated at the end of each cycle.

Repeat for the other side.

16.Rinse satellite with clean water. Reinstall one empty satellite under each brew chamber.

Brewer is ready to use.

671 76601 Owners Manual 9221 Dual Satellite Brewer

NOTE: Normally, silicone hoses do not need to be delimed. Should deliming hoses become necessary, Bloomfield recommends replacing the hoses.

13

Page 15
Image 15
Bloomfield 9220, 9221 owner manual Servicing Instructions