SERVICING INSTRUCTIONS (continued)
CAUTION:
SHOCK HAZARD
Disconnect brewer from electric power before opening the access panel.
Adjustments to be performed by qualified technician only.
NOTE:
Brewer is
1and
TIMER ADJUSTMENT
PRECAUTIONS: | Disconnect brewer from electric power. |
| Allow brewer to cool. |
FREQUENCY: | As required to adjust delivered volume |
TOOLS: | Phillips head screwdriver |
| Satellite or other container to calibrate volume |
1.Press HEATER ON/OFF switch to OFF. Turn POWER switch on back of brewer OFF.
2.Remove TOP PANEL. Operating controls are accessible through the top panel only.
3.Adjust the TIMER setting.
NOTE: Each side has its own timer. The LEFT TIMER is for the LEFT SIDE; the RIGHT TIMER is for the RIGHT SIDE.
Turn CLOCKWISE to increase time;
Turn
Adjust only in small increments to avoid large volume variations. Recommend no more than 1/16 turn.
4.Replace TOP PANEL. Turn POWER switch ON. Press HEATER ON/OFF switch to ON.
5.Allow the brewer to come up to brewing temperature, then perform a test brew. Check delivered volume. Readjust as necessary.
When desired volume is achieved, procedure is complete.
671 76601 Owners Manual 9221 Dual Satellite Brewer
14