Bloomfield 9221, 9220 Troubleshooting, Suggestions, Description Of Problem, Possible Cause

Models: 9220 9221

1 26
Download 26 pages 25.68 Kb
Page 18
Image 18
TROUBLESHOOTING

 

TROUBLESHOOTING

SUGGESTIONS

 

 

 

 

 

 

 

 

 

 

 

 

DESCRIPTION OF PROBLEM

 

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

No lights or heat

 

Unit not plugged in or circuit

Restore electric power

 

 

 

 

breaker tripped

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power switch OFF

Turn power switch ON

 

 

No heat

 

Hi-limit safety tripped

Allow brewer to cool, verify water

 

 

 

 

 

 

 

 

level, reset hi-limit

 

 

 

 

Thermostat damaged

Replace thermostat

 

 

 

 

Damaged hi-limit safety

Replace hi-limit

 

 

 

 

Damaged heater switch

Replace heater switch

 

 

 

 

Damaged heating element

Replace heating element

 

 

Brewer overflows

 

Water level probe corroded

Clean water level probe

 

 

 

 

Poor ground connection

Verify ground connection

 

 

 

 

Dirt in inlet valve or valve

Replace inlet valve

 

 

 

 

damaged

 

 

 

 

 

 

Brew valve damaged

Replace brew valve

 

 

 

 

Tank water boiling

Adjust or replace thermostat

 

 

Brew chamber overflows

 

Too many paper filters or wrong

Use one genuine Bloomfield

 

 

 

 

filter used.

paper filter per brew

 

 

 

 

Chamber discharge hole

Clean brew chamber

 

 

 

 

plugged

 

 

 

 

 

 

Timer not set properly

Set timer

 

 

 

 

Too much coffee or too fine a

Check with coffee supplier for

 

 

 

 

grind

recommended grind and quantity

 

 

Heats slow

 

Connected to wrong voltage

Verify supply voltage

 

 

 

 

Scale build-up on heating

De-lime hot water tank

 

 

 

 

elements

 

 

 

 

 

 

Damaged heating element

Replace element

 

 

Slow to fill

 

Insufficient water pressure

Brewer must be operated on a

 

 

 

 

 

 

 

 

dedicated water line. Other

 

 

 

 

 

 

 

 

equipment on line may be

 

 

 

 

 

 

 

 

robbing water volume.

 

 

 

 

Plugged water line strainer

Clean strainer

 

 

No heat to satellite

 

Warmer switch not on

Turn warmer switch on

 

 

 

 

Damaged element or wiring

Replace as required

 

 

 

 

 

 

 

 

 

 

 

 

Poor coffee quality

 

 

 

 

 

 

 

 

 

 

Keep brewer and servers clean.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install a taste and odor filter in water supply, and replace

 

 

 

 

 

 

cartridges regularly.

 

 

 

 

 

 

 

Use a quality coffee with a consistent roast. Use proper grind and

 

 

 

 

 

 

amount of coffee per brew.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

671 76601 Owners Manual 9221 Dual Satellite Brewer

Page 18
Image 18
Bloomfield 9221, 9220 owner manual Troubleshooting, Suggestions, Description Of Problem, Possible Cause, Suggested Remedy