CLEANING INSTRUCTIONS (continued)

PROCEDURE: Clean Satellite

CAUTION:

BURN HAZARD

671 76601 Owners Manual 9221 Dual Satellite Brewer

PRECAUTIONS:

Drain Satellite before Cleaning

FREQUENCY:

Twice Weekly

TOOLS:

Sight Glass Brush, Sanitizer

 

Soft Clean Cloth, Bucket

 

 

 

 

1.Remove and drain satellites. Remove lids.

2.Place 1 packet of Sanitizer into 2-1/2 gallons of warm tap water. Pour approximately 1 gallon of sanitizer solution into each satellite. Allow to stand for 2 minutes.

3.Drain sanitizer solution from satellite into the bucket.

4.Disassemble faucet. Brush clean with sanitizer solution. Reassemble faucet.

5.If necessary, disassemble and clean sight glass.

a.Push down on ears on sight glass guard . Then, pull ears forward. Lift guard off of retaining clip.

b.Remove sight glass tube from silicone elbow. Run the sight glass brush through the tube at least ten times.

c.Reassemble the tube to the silicone elbow. Be sure the elbow has not been pulled from the satellite body.

d.Reinstall the sight glass guard.

6.Reinstall lids. Install satellites on brewer.

7.Rinse satellites: With an empty brew chamber in place, press the BREW key and run 1 full cycle into each satellite.

8.Drain water from satellites.

Procedure is complete

Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns.

IMPORTANT:

DO NOT submerge satellite in water.

IMPORTANT:

DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the satellites.

Sight Glass

11

Page 13
Image 13
Bloomfield 9220, 9221 owner manual Cleaning Instructions, Procedure Clean Satellite