WARRANTY

xi

SPECIFICATIONS

1

FEATURES & OPERATING CONTROLS

2

PRECAUTIONS & GENERAL INFORMATION

4

AGENCY LISTING INFORMATION

4

INSTALLATION

5

OPERATION

7

BROILER CHART

9

TROUBLESHOOTING SUGGESTIONS

10

CLEANING INSTRUCTIONS

11

PARTS & SERVICE

13

CUSTOMER SERVICE DATA

13

 

 

Thank you for purchasing this Wells Bloomfield appliance.

Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.

This manual contains the information needed to properly install this appliance in a manner which will ensure its optimum performance.

162 303673 OpManual for Built-In Electric Charbroilers

 

 

 

 

AMPS PER LEG 3ø

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUT

AMPS

FIELD

MODEL

ELEMENT

VOLTS

KW

L1

L2

L3

.

WIRING

 

SINGLE

208

5.5

12.9

12.9

22.4

N/A

26.0

3ø 10 ga.

B-406

 

 

 

 

 

 

 

1ø 8 ga.

 

 

 

 

 

 

 

 

ASSEMBLY

240

5.5

11.2

11.2

19.4

N/A

22.5

90 g

 

 

 

 

 

 

 

 

 

 

 

SINGLE

208

5.5

11.5

22.4

14.4

N/A

26.0

3ø 10 ga.

B-446

 

 

 

 

 

 

 

1ø 8 ga.

 

 

 

 

 

 

 

 

ASSEMBLY

240

5.5

10.0

19.5

12.5

N/A

22.5

90 g

 

 

 

 

 

 

 

 

 

 

 

 

 

DUAL

208

11.0

30.0

30.0

30.0

N/A

-

3ø 8 ga.

B-506

 

 

 

 

 

 

 

1ø 4 ga.

ASSEMBLIES

240

11.0

26.0

26.0

26.0

N/A

45.0

 

90g

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Refer to appropriate Installation Instructions for equipment dimensions, cut-out dimensions, clearances, etc.

1

Page 3
Image 3
Bloomfield B-406, B-506, B-446 operation manual Neut Amps Field Model Element Volts Wiring