Installing Natural Gas Line

Installation should be done by a qualified service person.

CAUTION: If young children are in the area, a locking valve should be considered.

Connect Natural Gas Line

Before connecting, be sure that there is no debris caught in the head of the natural gas line, head of the grill natural gas line or in the head of the burner and burner ports.

Connect grill natural gas line to natural gas line.

Operating Instructions (continued)

Operating Side Burner

See your grill’s Owner’s Manual for Instructions. If you do not have the owner’s manual please call Customer Care at 1.800.762.1142 or visit www.bluerhino.com.

Operating Infrared Back Burner

See your grill’s Owner’s Manual for Instructions. If you do not have the owner’s manual please call Customer Care at 1.800.762.1142 or visit www.bluerhino.com.

Cleaning and Care

See your grill’s Owner’s Manual for Instructions. If you do not have the owner’s manual please call Customer Care at 1.800.762.1142 or visit www.bluerhino.com.

Disconnect Natural Gas Line

Before disconnecting make sure the natural gas line valve is “OFF”.Disconnect grill natural gas line from natural gas line.

Operating Instructions

Checking for Leaks

Figure 1

Burner

See your grill’s Owner’s Manual for Instructions. If you

venturi

pipe

do not have the owner’s manual please call Customer

 

Care at 1.800.762.1142 or visit www.bluerhino.com.

 

Limited Warranty

Blue Rhino Global Sourcing, Inc (“Vendor”) warrants to the original retail purchaser of this product, and to no other person, that if this product is assembled and operated in accordance with the printed instructions accompanying it, then for a period of one (1) year from the date of purchase, all parts in such product shall be free from defects in material and workmanship. Vendor may require reasonable proof of your date of purchase. Therefore, you should retain your sales slip or invoice. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service and which Vendor shall determine in its reasonable discretion upon examination to be defective. Before returning any parts, you should contact Vendor’s Customer Service Department using the contact information listed below. If Vendor confirms, after examination, a defect covered by this Limited Warranty in any returned part, and if Vendor approves the claim, Vendor will replace such defective part without charge. If you return defective parts, transportation charges must be prepaid by you. Vendor will return replacement parts to the original retail purchaser, freight or postage prepaid.

Burner Connections

1.Make sure the control valve and hose connections are securely fastened to the burner.

If your unit was assembled for you, visually check the connection between the burner venturi pipe and orifice. Make sure the burner venturi pipe fits over the orifice.

WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury or damage to property.

2.Please refer to diagram for proper installation. (Figures 1, 2 and 4)

3.If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance.

Gas Line Connection

1.Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.

2.Make sure control knobs are (OFF) position. (Figure 3)3.Connect natural gas line per “Installing Natural Gas Line” section.4.Turn “ON” natural gas main valve.4.Spoon leak check solution at all “X” locations (Figures 1, 2 and 4)

a.If any bubbles appear turn natural gas main valve “OFF”, reconnect and re-test.

b.If you continue to see bubbles after several attempts, turn natural gas main valve “OFF” and disconnect natural gas line and contact 1.800.762.1142 for assistance.

c.If no bubbles appear after one minute turn natural gas main valve “OFF”, wipe away solution and proceed.

X

Valve

Soft Pipe

Connection

Main Burners

Figure 2

Gas Valve with

Orifice

X

Valve

 

Soft Pipe

 

Connection

Side Burner

Figure 3

Gas Valve with Orifice

Gas

Connection

X

Burner venturi pipe

This Limited Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance or service by you or any third party, or failure to perform normal and routine maintenance on

the product as set out in this owner’s manual. In addition, the Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase.

This Limited Warranty is in lieu of all other express warranties. Vendor disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributors, including the warranty of merchantability or the warranty of fitness for a particular purpose.

VENDOR ALSO DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. VENDOR SHALL NO LIABILITY TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Vendor further disclaims any implied or express warranty of, and assumes no responsibility for, defects in workmanship caused by third parties.

This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some jurisdictions do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to everyone.

Vendor does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and no such representations are binding on Vendor.

Blue Rhino Global Sourcing, Inc Winston-Salem, North Carolina 27105 USA 1.800.762.1142

Figure 4

Operating Main Burners

See your grill’s Owner’s Manual for Instructions. If you

do not have the owner’s manual please call CustomerX Care at 1.800.762.1142 or visit www.bluerhino.com.

Operating Infrared Sear Burner

X

See your grill’s Owner’s Manual for Instructions. If you do not have the owner’s manual please call Customer Care at 1.800.762.1142 or visit www.bluerhino.com.