| page no. |
Contact 1.800.762.1142 for assistance. Do not return to place of purchase. | 11 |
| |
|
|
Installing LP Gas Tank
To operate you will need (1)
Note: An empty standard grill LP gas tank weighs approximately 18 lbs. A
Caution: LP gas tank must be properly disconnected and removed prior to moving this grill.
Insert LP Gas Tank
Place precision filled LP gas tank upright into hole in tnk tray so the tank valve is facing the gas line connection.
Installing Natural Gas Line
Installation should be done by a qualified service | Figure 1 |
person. |
|
CAUTION: If young children are in the area, a locking valve should be considered.
Connect Natural Gas Line |
|
| |
Before connecting, be sure that there is no debris |
|
| |
caught in the head of the natural gas line, head of the |
|
| |
grill natural gas line or in the head of the burner and | Figure 2 |
| |
burner ports. | Burner | ||
Back Burner Soft Pipe | |||
| |||
Connect grill natural gas line to natural gas line. | Connection | venturi | |
|
| pipe |
Secure LP Gas Tank
Secure tank by sliding tank retainer wire over shoulder of LP gas tank.
Disconnect Natural Gas Line
Before disconnecting make sure the natural gas line valve is “OFF”.
Disconnect grill natural gas line from natural gas line.
Operating Instructions
Checking for Leaks
Burner Connections
1.Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check the connection between the burner venturi pipe and orifice. Make sure the burner venturi pipe fits over the orifice.
WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property.
2.Please refer to diagram for proper installation. (Figures 2 and 3)
3.If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance.
X | X |
| |
|
| ||
Valve |
| LP Gas | |
Soft Pipe |
| ||
| Valve with | ||
Connection |
| ||
Main Burners | Orifice | ||
| |||
|
| ||
| Figure 3 |
|
LP Gas Valve | LP Gas |
with Orifice | Connection |
|
| X |
| X |
|
Valve |
|
|
Soft Pipe |
| Burner |
Connection | Side Burner | venturi |
|
| pipe |
Figure 4
Connect LP Gas Tank
Before connecting, be sure that there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner and burner ports.
Connect gas line to tank by turning knob clockwise until it stops.
Disconnect LP Gas Tank
Before disconnecting make sure the LP gas tank valve is “CLOSED”.
Disconnect gas line from LP gas tank by turning knob counterclockwise until it is loose.
Caution: LP gas tank must be properly disconnected and removed prior to moving this grill.
Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a precision filled one.
Tank/Gas Line Connection
1.Make
2.Make sure control knobs are (OFF) position.
(Figure 4)
3. LP: Turn LP gas tank valve to “OPEN”. |
|
NG: Turn “ON” natural gas main valve. | Figure 5a |
4.Spoon leak check solution at all “X” locations (Figures 2, 3, 5a and 5b)
a. LP: If any bubbles appear turn LP gas tank valve |
| X |
|
to “CLOSED”, reconnect and |
|
| |
NG: If any bubbles appear turn natural gas main |
| X | X |
valve “OFF”, reconnect and | X | ||
b. LP: If you continue to see bubbles after several | X |
| |
|
| ||
attempts, turn LP gas tank valve to “CLOSED” |
|
|
|
and disconnect LP gas tank and contact |
|
|
|
1.800.762.1142 for assistance. |
|
|
|
NG: If you continue to see bubbles after several |
|
|
|
attempts, turn natural gas main valve “OFF” |
| Figure 5b |
|
and disconnect natural gas line and contact |
|
|
|
1.800.762.1142 for assistance. |
|
|
|
c. LP: If no bubbles appear after one minute turn LP |
| X |
|
gas tank valve to “CLOSED”, wipe away solution |
|
| |
and proceed. |
|
| |
NG: If no bubbles appear after one minute turn |
| X |
|
natural gas main valve “OFF”, wipe away solution |
|
| |
and proceed. |
|
|
|