page no.

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

11

 

 

 

Installing LP Gas Tank

To operate you will need (1) precision-filled standard grill LP gas tank (20#) with external valve threads.

Note: An empty standard grill LP gas tank weighs approximately 18 lbs. A precision-filled standard grill LP gas tank should weigh no more than 38 lbs.

Caution: LP gas tank must be properly disconnected and removed prior to moving this grill.

Insert LP Gas Tank

Place precision filled LP gas tank upright into hole in tnk tray so the tank valve is facing the gas line connection.

Installing Natural Gas Line

Installation should be done by a qualified service

Figure 1

person.

 

CAUTION: If young children are in the area, a locking valve should be considered.

Connect Natural Gas Line

 

 

Before connecting, be sure that there is no debris

 

 

caught in the head of the natural gas line, head of the

 

 

grill natural gas line or in the head of the burner and

Figure 2

 

burner ports.

Burner

Back Burner Soft Pipe

 

Connect grill natural gas line to natural gas line.

Connection

venturi

 

 

pipe

Secure LP Gas Tank

Secure tank by sliding tank retainer wire over shoulder of LP gas tank.

Disconnect Natural Gas Line

Before disconnecting make sure the natural gas line valve is “OFF”.

Disconnect grill natural gas line from natural gas line.

Operating Instructions

Checking for Leaks

Burner Connections

1.Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.

If your unit was assembled for you, visually check the connection between the burner venturi pipe and orifice. Make sure the burner venturi pipe fits over the orifice.

WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property.

2.Please refer to diagram for proper installation. (Figures 2 and 3)

3.If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance.

X

X

 

 

 

Valve

 

LP Gas

Soft Pipe

 

 

Valve with

Connection

 

Main Burners

Orifice

 

 

 

 

Figure 3

 

LP Gas Valve

LP Gas

with Orifice

Connection

 

 

X

 

X

 

Valve

 

 

Soft Pipe

 

Burner

Connection

Side Burner

venturi

 

 

pipe

Figure 4

Connect LP Gas Tank

Before connecting, be sure that there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner and burner ports.

Connect gas line to tank by turning knob clockwise until it stops.

Disconnect LP Gas Tank

Before disconnecting make sure the LP gas tank valve is “CLOSED”.

Disconnect gas line from LP gas tank by turning knob counterclockwise until it is loose.

Caution: LP gas tank must be properly disconnected and removed prior to moving this grill.

Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a precision filled one.

Tank/Gas Line Connection

1.Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.

2.Make sure control knobs are (OFF) position.

(Figure 4)

3. LP: Turn LP gas tank valve to “OPEN”.

 

NG: Turn “ON” natural gas main valve.

Figure 5a

4.Spoon leak check solution at all “X” locations (Figures 2, 3, 5a and 5b)

a. LP: If any bubbles appear turn LP gas tank valve

 

X

 

to “CLOSED”, reconnect and re-test.

 

 

NG: If any bubbles appear turn natural gas main

 

X

X

valve “OFF”, reconnect and re-test.

X

b. LP: If you continue to see bubbles after several

X

 

 

 

attempts, turn LP gas tank valve to “CLOSED”

 

 

 

and disconnect LP gas tank and contact

 

 

 

1.800.762.1142 for assistance.

 

 

 

NG: If you continue to see bubbles after several

 

 

 

attempts, turn natural gas main valve “OFF”

 

Figure 5b

 

and disconnect natural gas line and contact

 

 

 

1.800.762.1142 for assistance.

 

 

 

c. LP: If no bubbles appear after one minute turn LP

 

X

 

gas tank valve to “CLOSED”, wipe away solution

 

 

and proceed.

 

 

NG: If no bubbles appear after one minute turn

 

X

 

natural gas main valve “OFF”, wipe away solution

 

 

and proceed.