Outdoor LP Gas Barbecue Grill Model No. GBC621C

Installing LP Gas Tank

To operate you will need (1) precision-filled standard grill LP gas tank (20#) with external valve threads.

Insert LP Gas Tank
Operating InstructionsChecking for Leaks

Burner Connections

Place precision filled LP gas tank into hole in grill body upright so it is arranged for vapor withdrawal.

Secure LP Gas Tank

Secure tank by sliding tank retainer wire over shoulder of LP gas tank.

Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.

If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice.

WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property.

Please refer to diagram for proper installation.

If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance.

Tank/Gas Line Connection

Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.

Make sure control knobs are off. Turn LP gas tank ON at valve.

Spoon leak check solution at all “x” locations

Gas Valve with orifice

Burner

Venturi

Gas

Connections

Main Burners

Gas

Connections

Burner

Venturi

Gas Valve with orifice

Side Burner

X

X

X

X

X

Connect LP Gas Tank

Before connecting, be sure that there is no debris caught in the head of the gas tank, head of the regulator valve or in the head of the burner and burner ports.

Connect gas line to tank by turning knob clockwise until it stops.

If any bubbles appear turn LP gas tank OFF, reconnect and re-test. If you continue to see bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for assistance.

If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.

Operating Main Burners

Lighting

 

 

 

 

 

1. Open lid. Attempting to light the

 

 

 

 

 

 

 

 

 

 

burner with the lid closed may

 

 

 

 

 

cause an explosion!

 

 

 

 

 

2. Make sure there are no

 

 

 

1/2"

obstructions of airflow to the gas

Flame

12.7 mm

unit. Spiders and insects can nest

 

 

 

 

 

 

1/4"

within and clog the burner / venturi

Burner

 

 

 

 

 

6.4mm

tube at the orifice. A clogged

 

 

 

 

 

 

 

burner tube can lead to a fire

 

 

 

 

0"

beneath the appliance.

 

 

 

 

 

 

0mm

3. All control knobs must be in the

 

 

 

 

 

Main burner proper flame height.

 

 

 

 

OFF position.

 

 

 

 

 

 

 

 

 

4.Turn on gas at LP gas tank.

5.Push and turn control knob counterclockwise to HIGH.

6.Press the electronic igniter button and hold for 5 seconds to light burner.

7.If ignition does not occur in 5 seconds, turn burner control knob OFF, wait 5 minutes, and repeat lighting procedure.

8.If igniter does not light burner, use a lit match secured with the lighting rod provided to light burners manually. Access the burners through the cooking grid and heat plates. Position the lit match near side of the burner.

Important: Always use the lighting rod provided when lighting burners with a match.

9.After lighting, observe the burner flame, make sure all burner ports are lit and flame height matches illustration.

CAUTION: If burner flame goes out during operation, immediately turn the gas “OFF” and open lid to let the gas clear for about 5 minutes before re-lighting.

Turning Off

1.Turn all control knobs clockwise to the OFF position one at a time.

2.Turn gas off at LP tank.

Initial Use

Before cooking on this grill for the first time, operate the grill for about 15 minutes with the lid closed and the gas turned on “HIGH.” This will “heat clean” the internal parts and dissipate odor from the manufacturing processes.