Bogen PEQ1R Module Installation, Jumper Selections, Module Features, Priority Level, Input

Models: PEQ1R

1 3
Download 3 pages 20.35 Kb
Page 2
Image 2
Module Installation

Module Installation

Jumper Selections

1. Turn off all power to the unit.

2.Make all necessary jumper selections.

3.Position module in front of desired output module bay opening, making sure that the module is right-side up. Output modules will not fit in input module bays. Do not force an output module into an input module bay.

4.Slide module on to card guide rails. Make sure that both the top and bottom guides are engaged.

5.Push the module in to the bay until the faceplate con- tacts the unit’s chassis.

6.Use the two screws included to secure the module to the unit.

WARNING:

Turn off power to unit and make all jumper selections before installing module in unit.

Priority Level

Jumper placement only affects the unbalanced input signal. The jumper placement determines whether the module’s input can be muted or not by other input modules.When enabled, the input is permanently set to the lowest priority level.

Module Features

The PEQ1R is a 4-band equalizer that provides 2 bands of para- metric equalization control with adjustments for filter bandwidth (‘Q’), filter center frequency, and cut or boost level.

The two parametric bands overlap in frequency in order to allow greater flexibility in spectrum shaping. A fixed Treble and Bass control allows cut or boost control over the upper (>10 kHz) and lower (<100 kHz) portions of the audio spectrum.

An EQ switch allows the signal processing to be switched in and out of the system for quick comparisons of the before and after effects of the equalization.

All Bogen output modules include an unbalanced input that is controlled by the amplifier’s input control so that the user is not penalized in number of inputs when using an output module.

‘Q’ Control (Lo-Mid & Hi-Mid Bands)

Provides control over the ‘Q’ (bandwidth) of the two parametric filters. ‘Q’ is

continuously adjustable from 1.5 octaves ( Jumper Selections ) to 1/6 ( Priority Level ) octave.The Q control can meet both wideband and narrow-band equalization requirements.

Bass and Treble Controls

Provides control over Bass and Treble boost or cut. Gain range of -12 dB to +12 dB at 100 Hz for the Bass and at 10 kHz for the Treble.

Input

The RCA unbalanced input provides a 20k-ohm input impedance.The unbal- anced input connects to the amplifier’s front level control for the bay in which it is installed so that the input is not lost when using the output mod- ule.

Frequency Control (Lo-Mid & Hi-Mid Bands)

Provides control over the center frequency of the 2 parametric filters with a frequency range of 200 Hz to 4kHz (Lo-Mid) and 1K to 8K (Hi-Mid).

Gain Control (Lo-Mid & Hi-Mid Bands)

Provides control over the boost or cut of the two parametric filters. The gain has a range of -14dB to +14dB.

Equalizer Bypass Switch

The Equalizer Bypass Switch provides instant comparison between equaliza- tion and no equalization during the tuning of the system.

Page 2
Image 2
Bogen PEQ1R Module Installation, Jumper Selections, Module Features, Priority Level, ‘Q’ Control Lo-Mid& Hi-MidBands