Ceiling Speaker Enclosure & Tile Bridge Models RE84 and TB8
Installation and Use Manual
UL LISTED (UUMW)
For Use In Return Air Ceiling Plenum Spaces
Enclosures (UL Listed) | RE84 |
Intended for use with: | TB8 (Tile Support Bridge) |
RE84 Features
• Listed by Underwriters Laboratories, Inc. Category UUMW. Material and construction permits use where ceiling plenum is part of the air handling system.
• Compound knockout(s) provided for listed type metallic type fittings for 1/2" and 3/4" plenum rated cable and plenum whip flex conduit.
• | Four horseshoe tab slots provided on each enclosure to mate with |
| |
| four horseshoe tabs on TB8 bridge eliminates the need for |
| |
|
| ||
| screws. | RE84 | |
• | Two seismic | ||
|
TB8 Features
•Distributes the weight of a speaker, grille, and protective enclosure onto the ceiling grid.
• Four locator tabs to prevent sliding on ceiling tile.
• Four horseshoe tabs to mate with four horseshoe tab slots on enclosure.
A Listed assembly requires that the enclosed loudspeaker is not exposed within the air handling plenum. Wiring, and/or conduit enclosure entry fittings, and installation must comply with local codes. Many local codes require a separate enclosure assembly with
NOTE: All cable splices and connections to Speaker/Transformer | TB8 |
pigtails must be made inside of Listed enclosure. |
|
NOTE: When the RE84 and the TB8 are installed together, the clearance holes on the TB8 are used during installation. However, when the TB8 is installed without the RE84, the threaded holes on the TB8 are used during installation.
© 2004 Bogen Communications, Inc. All rights reserved.
Specifications subject to change without notice.