6Speaker Safety Cable and Tether Link Attachment Installation ![]()
![]()
![]()
A)Find the SAFETY ATTACHMENT POINT located on the rear of the A8/A12 Speaker. Using the (1/4”- 20 x 1/2”) HEX SOCKET SAFETY BOLT and the LOCK WASHER, secure the SAFETY TETHER LINK into the Safety Attachment Point, vertically,
as shown.
B)POLE MOUNT (TOP-DOWN  VIEW)
SAFETY
![]()
 TETHER LINK
SAFETY ATTACHMENT 
 POINT
SPEAKER MOUNTING BRACKET ![]()
![]()
A8/A12
LOUDSPEAKER
POLE
 SAFETY
TETHER LINK
8 FT. SAFETY CABLE  | ADJUSTABLE  | |
WIRE CLAMP  | ||
  | 
WHEN INSTALLATION IS FINISHED, THE SAFETY CABLE SHOULD BE TAUT. CABLE SLACK SHOWN IN DRAWING IS FOR ILLUS- TRATIVE PURPOSES ONLY.
Take the 8 FT. SAFETY CABLE and loop it tightly around the Pole/Post 
C) WALL MOUNT (TOP-DOWN  VIEW)
Take the 8 FT. SAFETY CABLE and feed it through the Tie Slots (see figure A in Section 2 for Tie Slot location) of the mounted Stationary Mounting Bracket, then into the open hole of of the Safety Tether Link. Pull the Cable taut, leaving very little slack, and secure the Cable ends using the ADJUSTABLE WIRE CLAMP.
WHEN INSTALLATION IS FINISHED, THE SAFETY CABLE SHOULD BE TAUT. CABLE SLACK SHOWN IN DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY.
WALL
8 FT.  | SPEAKER  | 
SAFETY  | MOUNTING  | 
CABLE  | BRACKET  | 
A8/A12
LOUDSPEAKER
TIE 
 SAFETY
SLOT 
 TETHER LINK
ADJUSTABLE
WIRE CLAMP