Bolens No. 247.770550 Troubleshooting, Problem Possible Causes Corrective Action

Models: No. 247.770550

1 21
Download 21 pages 22.57 Kb
Page 17
Image 17

TROUBLESHOOTING

Problem

Possible Cause(s)

Corrective Action

 

 

 

 

 

Engine fails to start

1.

Fuel tank empty or stale fuel.

1.

Fill tank with clean, fresh gasoline. Fuel will not

 

 

 

 

last over thirty days unless a fuel stabilizer is

 

 

 

 

added.

 

2.

Spark plug wire disconnected.

2.

Connect wire to spark plug.

 

3.

Cannot pull recoil cord.

3.

Obstruction lodged in impeller. Disconnect

 

 

 

 

spark plug wire and remove lodged object.

 

4.

Choke not in ON position.

4.

Move CHOKE to ON position.

 

5.

Faulty spark plug.

5.

Clean, adjust gap or replace.

 

6.

Safety switch not depressed.

6.

Safety switch must be depressed by the front

 

 

 

 

tab on the bag handle when securing the bag.

 

7.

Safety switch wire is not

7.

Connect safety switch wire to engine connector

 

 

connected to engine or not

 

and ground to mounting bracket.

 

 

properly grounded.

 

 

 

 

 

 

 

Loss of power;

1.

Spark plug wire loose.

1.

Connect and tighten spark plug wire.

operation erratic

2.

Unit running on CHOKE.

2.

Move choke lever to OFF position.

 

3.

Blocked fuel line or stale fuel.

3.

Clean fuel line; fill tank with clean fresh

 

 

 

 

gasoline. Fuel will not last over thirty days

 

 

 

 

unless a fuel stabilizer is used.

 

4.

Water or dirt in fuel system.

4.

Disconnect fuel line at carburetor to drain fuel

 

 

 

 

tank. Refill with fresh fuel.

 

5.

Carburetor out of adjustment.

5.

Contact your Sears Service Center.

 

6.

Low engine RPM.

6.

Always run engine at full throttle.

 

 

 

 

 

Too much vibration

1.

Loose parts or damaged

1.

Stop engine immediately and disconnect spark

 

 

impeller.

 

plug wire. Have unit serviced by a Sears

 

 

 

 

Service Center.

 

 

 

 

 

Engine overheats

1.

Carburetor not adjusted

1.

Contact your Sears Service Center.

 

2.

Engine oil level low

2.

Fill crankcase with proper selection of oil.

 

 

 

 

 

Unit does not

1.

Discharge chute clogged.

1.

Stop engine immediately and disconnect spark

discharge

 

 

 

plug wire. Clean flail screen and inside of

 

 

 

 

discharge opening. See Maintenance section of

 

 

 

 

this manual.

 

2.

Foreign object lodged in

2.

Stop engine immediately and disconnect spark

 

 

impeller.

 

plug wire. Remove lodged object.

 

3.

Low engine RPM.

3.

Always run engine at full throttle.

 

4.

Vacuum bag is full.

4.

Empty bag.

 

 

 

 

 

Rate of discharge

1.

Low engine RPM.

1.

Always run engine at full throttle.

slows considerably or

2.

Chipper blade dull.

2.

Replace chipper blade or see your Sears

composition of

 

 

 

Service Center.

discharged material

 

 

 

 

changes

 

 

 

 

 

 

 

 

 

NOTE: For repairs beyond the minor adjustments listed above, please contact your local Sears Service Center.