Bosch Appliances 1200 installation manual Correcting an Overheat/Fan Fail Condition

Models: 1200

1 24
Download 24 pages 15.59 Kb
Page 8
Image 8

8

en System Interface

1200 Series IP Video Storage System

 

 

 

explains what each LED indicates when illuminated and any corrective action you may need to take.

HDD: Indicates IDE channel activity. SAS/SATA drive activity when flashing.

NIC1: Indicates network activity on GLAN1 / 2 when flashing.

Overheat/Fan Fail: This LED indicates a fan failure when flashing.

When Continuously On (not flashing): This LED indicates an overheat condition caused by cables obstructing the airflow in the system or the ambient room temperature being too warm.

Correcting an Overheat/Fan Fail Condition

1.Check the routing of the cables and move any cables the restrict airflow.

2.Confirm that all fans are operating normally.

3.Verify that the heatsinks are installed properly.

4.If the chassis cover is not aligned correctly, the airflow may be disrupted. This leads to overheating. Confirm that the chassis cover is placed correctly.

5.This LED will remain active as long as the overheat condition exists.