2.Cold water is mixing with the hot water between the AquaStar and the outlet

See #4 under “NO SPARK AT THE PILOT”.

3.Inlet water pressure is erratic due to inadequate supply water pressure or saturated pressure tank on well system

Check the inlet water pressure. On a private well, raise minimum pressure setting to 30 psi. Confirm that the pressure tank is not water logged.

4.Gas pressure is too low

See page 2 and 7 for correct specifications.

Fig. 14 - Diagram of AquaStar 125 X

3

2

5

6

7

 

8

 

 

 

 

11

 

 

 

1.

Heat exchanger

7.

Electronic control box

 

2.

Pilot assembly

8.

Battery box

 

3.

Burner manifold gas

9.

on/off switch

 

 

pressure test nipple

10.

Temperature adjustment selector

 

4.

Main gas burner

11.

Microswitch

12

5.

Pilot gas tubing

12.

Gas inlet gas pressure test nipple

 

6.

Gas valve

13.

LED

 

1

4

9

13

10

13

Page 13
Image 13
Bosch Appliances 125X LP, 125X NG Gas pressure is too low, See page 2 and 7 for correct specifications