Maintenance and service

pipe (approx 1.5" inserted). Avoid air gaps between probe and measuring port as it can alter readings.

Fig. 40 Measuring port

BWhile holding the Program (P) button, turn the ON/ OFF switch to ON (I) position (see Fig. 41). As soon as ‘188’ flashes on the display, release the Program button. The display should now read P2. Press button until “P1” appears on display.

 

 

CO2 level

Max CO

 

 

level

 

 

 

 

 

Nat. Gas

 

max. input

P1

9.7 ± 0.3 %

300 ppm

min. input

P2

9.5 ± 0.5 %

 

 

 

LP Gas

 

max. input

P1

10.7 ± 0.3 %

300 ppm

min. input

P2

10.5 ± 0.5 %

 

* Final reading must be confirmed with the front cover on, CO2 levels increase when the cover is installed.

Table 9

1. If P1 CO2 level is off:

BLoosen yellow painted philips screw (1) and cover should rotate down (2) revealing a recessed brass slotted screw. Fig. 42.

B Turning the slotted screw counter clockwise will raise P1 CO2 levels and clockwise will lower P1 CO2 levels. Adjustments to the slotted screw will also change P2 CO2 levels.

BAfter bringing the P1 CO2 readings in range, press

the button to enter the P2 mode. Verify CO2 readings in P2 mode.

Fig. 41

B. Measuring CO2 (Cover Installed):

BOpen all hot water taps to achieve a flow rate of at least 4 gallons per minute. (1 tub and 2 sinks should be sufficient).

B Record the CO2 reading in P1 below. (Analyzer reading may take several minutes to stabilize).

BPress the ‘ ’ button until P2 appears. Unit will ramp down to low fire and the water flow should decrease.

BRecord the CO2 reading in P2 below.

P1 CO2 Reading:

 

% CO2

P2 CO2 Reading:

 

% CO2

 

 

 

 

C. Adjusting CO2 (cover removed):

Note: when making adjustments with the front cover off, CO2 values will be 0.3 - 0.5% lower than with the front cover on. Adjust values accordingly to make target num- bers in Table 10 when cover is secured.

Compare your readings to those found in Table 10. If CO2 readings are off, make adjustments as outlined below.

Note: P1 adjustment will change the P2 reading. Con- firm the P1 value BEFORE adjusting the P2 level.

Fig. 42 Adjusting P1 CO2 level

2. If P2 CO2 level is off:

BRemove yellow painted #40 Torx cover from the front of the gas valve. (Fig. 43) A plastic #40 Torx screw will be revealed.

B Turning the plastic #40 Torx screw counter clockwise will lower P2 CO2 levels and clockwise will raise P2 CO2 levels.

Note: These screw adjustment are very sensitive and may take several minutes to stabilize.

30

6 720 608 263

Page 30
Image 30
Bosch Appliances 2400E NG, 2400E LP manual Measuring CO2 Cover Installed, Adjusting CO2 cover removed

2400E NG, 2400E LP specifications

Bosch Appliances has long been synonymous with quality and innovation in the kitchen appliance sector. Among their impressive lineup, the Bosch 2400E LP (Liquid Propane) and 2400E NG (Natural Gas) models stand out as prime examples of the brand’s commitment to performance and functionality.

Both the 2400E LP and 2400E NG are designed with user convenience and culinary excellence in mind. One of the most notable features of these appliances is their exceptional heat distribution, which ensures that food cooks evenly. This is particularly beneficial for grilling, where inconsistent heat can lead to unevenly cooked meals. The burners are crafted to provide high-efficiency performance while consuming less fuel, making them an economical choice for both home cooks and culinary enthusiasts.

Each model boasts a sleek, modern design that can seamlessly integrate into various kitchen styles. The stainless steel construction not only enhances aesthetics but also increases durability, ensuring the appliance can withstand the rigors of daily use while maintaining its appearance. The 2400E series also features a compact size, making it suitable for kitchens of all dimensions, including those with space constraints.

In addition to design and performance, safety features are a priority for Bosch. The 2400E models come equipped with sturdy flame control knobs, allowing users to adjust heat settings with precision, reducing the risk of accidental flare-ups. Moreover, the integrated ignition system is designed for reliability, ensuring that starting the unit is hassle-free.

Versatility is another hallmark of the Bosch 2400E LP and NG models. These appliances are compatible with a range of cooking accessories, from griddles to rotisserie attachments, providing multiple cooking methods to satisfy diverse culinary endeavors. The grease management system is another highlight, simplifying cleanup and maintenance after cooking sessions.

Another innovative technology in the Bosch 2400E series is the Smart Grilling feature, which includes temperature sensors that provide real-time feedback. This allows users to monitor cooking progress effortlessly, enhancing the overall cooking experience. The models also include a robust warranty, ensuring peace of mind for consumers.

In conclusion, Bosch Appliances’ 2400E LP and NG models represent a fine balance of innovation, safety, and style. With their powerful cooking capabilities, thoughtful design features, and user-friendly technologies, they stand as excellent choices for anyone looking to elevate their cooking experience.