38 en On-Screen Display (OSD) Menus (Bosch Protocol)MIC Series 550 Camera

 

 

Communication Setup Menu Choices:

 

 

 

 

 

 

 

 

 

 

Menu

Description

Submenu / Description

Default

 

 

 

 

 

Setting

 

 

Exit

Saves and exits the menu.

 

 

 

 

AutoBaud

Turns on AutoBaud detection,

Toggles ON or OFF.

ON

 

 

 

which detects and adjusts the

ON automatically accepts baud

 

 

 

 

camera protocol and baud rate

rates from 2400 to 57600.

 

 

 

 

to match that of the controller.

(Note: If stepping from 2400 to

 

 

 

 

 

57600 baud, you must first set

 

 

 

 

 

the Baud Rate to 19200 for

 

 

 

 

 

AutoBaud to detect the higher

 

 

 

 

 

baud rate.)

 

 

 

Baud Rate

Manually sets the baud rate

Choices are 2400, 4800, 9600,

9600

 

 

 

when AutoBaud is set to OFF.

19200, 38400, and 57600.

 

 

 

Bilinx

Turns on Bilinx control

Toggles ON or OFF.

ON

 

 

 

communication.

 

 

 

 

 

(Only available when not

 

 

 

 

 

connected to a Bilinx data

 

 

 

 

 

interface unit.)

 

 

 

 

 

 

 

 

 

 

Restore Defaults

Restores the default settings for

 

 

 

 

 

this menu only.

 

 

 

 

 

 

 

 

7.6

Alarm Setup

 

 

 

The Alarm Setup Menu contains alarm inputs, outputs and rules.

NOTICE!

The maximum number of Alarm Inputs is eight (8), available only on the Alarm and Washer Pump Drive Card (MIC-ALM) (sold separately). This card is available for non-IR power supply units (PSUs) only. Without the MIC-ALM installed in the MIC PSU, only one alarm input is available on non-IR PSUs. IR PSUs have 4 alarm inputs available. See Section 5.6.2 Alarm Inputs and Outputs, page 22 for the specific number of alarm Inputs and Outputs per PSU.

Alarm Setup

 

 

Inputs Setup

 

Exit...

 

Exit...

 

 

Inputs Setup...

 

1.

Alarm Input 1

N.O.

 

Outputs Setup...

 

2.

Alarm Input 2

N.O.

 

Rule Setup...

 

3.

Alarm Input 3

N.O.

 

Restore Defaults...

 

4.

Alarm Input 4

N.O.

 

 

 

5.

Alarm Input 5

N.O.

 

 

 

6.

Alarm Input 6

N.O.

 

 

 

7.

Alarm Input 7

N.O.

 

 

 

8.

Alarm Input 8

N.O.

 

 

 

9. NONE

 

 

 

 

10. NONE

 

 

 

 

11. NONE

 

 

 

 

12. NONE

 

 

 

 

 

Focus / Iris: Select Type

 

Focus / Iris: Select

 

 

Right / Left: Select Mode

 

 

 

 

 

 

 

F.01U.239.454 3.0 2012.09