Bosch Appliances 550 Preset Commands Forward Vision Protocol, Preset Command Description Number

Models: 550

1 66
Download 66 pages 32.18 Kb
Page 62
Image 62

62 en MIC Series 550 Camera

Keyboard

User Action

Description

Command

 

 

 

 

Press and hold

Initiates recording based upon current Recording

 

 

(2 seconds)

setting (A or B) in the Setup Menu. Press ACK to end

0

- Pattern

 

recording.

 

 

 

 

 

 

Press

Initiates recording continuous playback based upon

 

 

 

current Recording setting (A or B) in the Setup Menu.

 

 

 

 

 

 

Press and hold

Initiate Recording A. Press ACK to end recording.

1

- Pattern

(2 seconds)

 

 

 

 

 

 

 

Press

Initiate Recording A continuous playback

 

 

Press and hold

Initiate Recording B. Press ACK to end recording.

2

- Pattern

(2 seconds)

 

 

 

Press

Initiate Recording B continuous playback

3

- Pattern

Press

Initiate the AutoDome standard preset tour (Tour 1)

4

- Pattern

Press

Initiate the AutoDome custom preset tour (Tour 2)

1

- Aux On / Aux Off

Press

Activates / deactivates selected wiper mode or Alarm

 

 

 

Output 1.

2

- Aux On / Aux Off

Press

Activates / deactivates alarm output 2

3

- Aux On / Aux Off

Press

Activates / deactivates alarm output 3

4

- Aux On / Aux Off

Press

Activates / deactivates alarm relay

91 - Aux On

Press

Activate Zone Scan (display zone titles)

92 - Aux On

Press

Activate Zone Scan (display zone titles)

A.3

Preset Commands (Forward Vision Protocol)

 

 

 

 

 

Preset

Command

Description

 

Number

 

 

 

1

Auto Home Position

After a certain amount of time--programmable--with no

 

 

 

manual control, the camera moves to the home

 

 

 

position (Preset 1). When this function is turned off,

 

 

 

the camera remains stationary until the next user input.

 

 

 

 

 

62

Wash Wipe Position

If Wash Wipe is On, then, when the Wash auxiliary is

 

 

 

set, the camera returns to a preset Wash Position,

 

 

 

activates the washer relay in the PSU, and turns on the

 

 

 

wiper. When the auxiliary is off, the camera returns to

 

 

 

its prior position and turns off the wiper. If Wash Wipe

 

 

 

is Off, then, when the aux is activated, the camera

 

 

 

closes the washer relay and remains in its current

 

 

 

position.

 

 

 

 

 

85

On Screen menu

Displays the On Screen Menu.

 

86

Self Diagnosis

Runs rudimentary tests indicating any faults with the

 

 

 

unit. The test begins with the unit moving to a specified

 

 

 

test position and then checking for valid resolver

 

 

 

readings and reliable camera module communications.

 

 

 

Then, the pan and tilt drives and camera zoom are

 

 

 

tested. Finally, the wiper is activated. The results of

 

 

 

each test are displayed as completed.

 

 

 

 

 

87

Play Pattern One

Play Pattern 1

 

88

Stop Pattern One

Stop Pattern

 

89

Record Pattern One

Record Pattern 1

 

90

Play Pattern Two

Play Pattern 2

 

91

Stop Pattern Two

Stop Pattern 2

 

92

Record Pattern Two

Record Pattern 2

F.01U.239.454 3.0 2012.09

User Manual

Bosch Security Systems, Inc.

Page 62
Image 62
Bosch Appliances 550 user manual Preset Commands Forward Vision Protocol, Preset Command Description Number