D7024
Panel Programming
These menu items are only allowed at the local keypad.
The following window will appear:
OPTION BUS (M/M)
1- UPDATE BUS
2- SETUP KEYPDS
Press [1] to program system to update bus. After you have programmed Update Bus, the following window will appear:
UPDATE COMPLETE
TOT BUS DEVS: X
Then the previous window will appear.
7.3.3.2 Setup Keypad
Shortcut:
This feature tells the system how many keypads should be supervised. It automatically performs an update bus operation as it completes.
OPTION BUS
1- UPDATE BUS
2- SETUP KEYPDS
Press [2] to set up keypads. The following window will appear:
#OF KEYPADS (__)
Enter the desired value and press [#]. The current setting is displayed in parentheses on the first line. After you set up the keypads, the update bus operation proceeds (see above), then the previous window will display.
7.3.4PIN REQUIRED
7.3.4.1 Local
Shortcut:
A PIN can be required before operations can be performed using the local,
The following window will appear:
PIN REQUIRED?
1- LOCAL
2- REMOTE
Press [1] to require a PIN at the local keypad. The following window will appear:
LOCAL KEYPD PIN?
____:YES(1)NO(2)
Press the number key that corresponds to your selection. The current setting is displayed in front of the colon on the second line. After making your selection, the previous window will display.
7.3.4.2 Remote
Shortcut:
The following window will appear:
PIN REQUIRED?
|
| 1- | LOCAL |
|
|
|
|
| 2- | REMOTE |
|
|
|
|
|
|
|
| D7024 Operation and Installation Guide |
|
|
|
|
|
|
| |
| © 2005 Bosch Security Systems | Page 51 | 41740F |