Access Control Interface Module

Strike Profile en 11

 

 

Yes Programmed shunt time will activate so door can be manually opened.

No Request to Enter [RTE] automatically activates the programmed strike and shunt time.

NOTICE!

Use this parameter when a user can open a door manually without relying on a token/card to activate the strike (such as with a “push bar”).

NOTICE!

When RTE Shunt Only is [Yes] Request To Enter events are not logged, reported, or printed.

D# REXShunt Only?

Default:No

Selections:

Yes or No

 

 

Use this program item to disable the strike, but still activate the programmed shunt time upon a Request to Exit an area.

Yes Programmed shunt time will activate so door can be manually opened.

No Request to Exit [REX] automatically activates the programmed strike and shunt time.

NOTICE!

When REX Shunt Only is [Yes] Request To Exit events are not logged, reported, or printed.