6

en Door Profile

Access Control Interface Module

 

 

 

1-8This CC# Scope determines disarming rights. The user’s access level in conjunction with the CC # Scope will determine which areas will be disarmed.

Blank Only the area assigned to the D# Entry Area will disarm for this door.

D# Door Point

Default:Blank

Selections:

Blank, 1-127, 129-247

 

 

Enter the point number that will be assigned to this door. This point cannot be used for any other point assignments.

NOTICE!

Door Points must be programmed as Perimeter Points. If a 24 hour point type is required for the Door Point, you may use a Perimeter Point Type with a Point Response of 9 - C. Also, the Debounce Count must be set to 4 in Point Assignments.

1-127,129-247The point number assigned to this door. Points 128 and 248 are reserved by the panel for internal use.

Blank There is no point number assigned to this door.

NOTICE!

When assigning points 1to 8 (panel zones), the end of line resistors must be removed from the panel

NOTICE!

Do not enable any POPIT points (or OctoPOPIT points) sharing the same point number as the Door Point. Failure to do so will result in Extra Point trouble conditions upon reboot.

D# Interlock Point

Default:Blank

Selections:

Blank, 1-127, 129-247

 

 

Enter the interlock point number. This point, when faulted, will prevent the door controller from allowing access upon a valid ID read or door request.

Do not assign this point as a door point to another door point. You may assign it to another controller thereby having one interlock point prevent multiple controllers from activating.

1-127,129-247The point number assigned to this door. Points 128 and 248 are reserved by the panel for internal use.

Blank There is no point number assigned to this door.

NOTICE!

The interlock point will be considered in a normal state if it is bypassed swinger bypassed or forced armed. This will result in normal operation of access even if the door is left open.

F.01U.201.526 02 2011.10

Program Entry Guide

Bosch Security Systems, Inc.

Page 6
Image 6
Bosch Appliances D9210C manual # Door Point, # Interlock Point