Bosch Appliances D9210C manual # Enter Request?, # Exit Request?

Models: D9210C

1 18
Download 18 pages 39.32 Kb
Page 13
Image 13

Access Control Interface ModuleEvent Profile en 13

D# Enter Request?

 

Default:

No

Selections:

Yes or No

 

 

This program item determines if Request to Enter [RTE] events are sent to the panel for processing memory, printing, and remote reporting.

Yes A DOOR REQUEST TO ENTER event from this door controller is sent to the panel for processing.

No A DOOR REQUEST TO ENTER event from this door controller is not sent to the panel for processing.

NOTICE!

RTE events require D# Access Granted to be programmed [YES].

D# Exit Request?

 

Default:

No

Selections:

Yes or No

 

 

This program item determines if Request to Exit [REX] events are sent to the panel for processing memory, printing, and remote reporting.

Yes DOOR REQUEST TO EXIT event from this door controller is sent to the panel for processing.

No A DOOR REQUEST TO EXIT event from this door controller is not sent to the panel for processing.

NOTICE!

REX events require D# Access Granted to be programmed [YES].

Bosch Security Systems, Inc.

Program Entry Guide

F.01U.201.526 02 2011.10

Page 13
Image 13
Bosch Appliances D9210C manual # Enter Request?, # Exit Request?