![](/images/new-backgrounds/1068953/689531x1.webp)
Installation Instructions
DS820i/DS820iT Series
TriTech PIR/Microwave Intrusion Detectors with Pet Immunity
1.0Description
The DS820i and DS820iT Series are high performance TriTech Passive Infrared (PIR)/Microwave (MW) Intrusion Detectors which use advanced signal processing to provide outstanding catch performance and unsurpassed false alarm immunity. They are designed to detect movement of a human body in the interior of a structure as it moves across the Detector’s field of view. When motion is detected, the Detector sends an alarm signal to the control panel. With Bosch Security Systems Pet Friendly® pet immunity, these Detectors will not detect a dog up to 100 pounds (45 kg) or two 60 pound (27 kg) dogs, up to 10 cats, numerous rodents or flying birds. This pet immunity feature has not been tested by Underwriters Laboratories.
2.0Specifications
•Input Power: 6 to 15 VDC, 16 mA nominal standby (up to 35 mA during walk testing and alarm). Use only Limited Power Source up to 5 A maximum.
•Standby Power: No internal standby battery. For UL Certificated installations, 4 hours (64 mAh) standby power must be provided by the control unit or by a Listed burglary power supply.
•Alarm Relay: Silent operating Normally Closed reed relay. Contacts
rated 3 W, 125 mA, 28 VDC maximum for DC resistive loads; and protected by a 4.7 Ω , 1/2 W resistor in the common “C” leg of the relay. Do not use with capacitive or inductive loads.
•Temperature: The storage and operating temperature range is
•Microwave Frequency:
DS820i/820iT: 10.525 GHz (UL Listed)
DS820iTA:10.687 GHz (Export only, not UL Listed)
DS820iTB:9.9 GHz (Export only, not UL Listed)
•Coverage:20 ft. by 20 ft. (6 m by 6 m)
•Tamper:(“T” models only) Normally Closed (with cover on). Contacts rated at 28 VDC, 125 mA max. Connect tamper circuit to a
• Options: | B335 Low Profile Swivel Mount Bracket , B338 Ceiling |
| Mount Bracket. (The use of brackets is not |
| recommended for pet applications and may reduce |
| range and increase dead zone areas). |
•Patents:This product is covered by one or more of the following U.S. patents: #4,660,024, #4,764,755, #5,077,548, #5,208,567, #5,262,783, #5,450,062, and #5,670,943. Other patents pending.
3.0Installation
3.1Remove the cover using
a small flat-blade screwdriver.
Bottom of Detector
Optional
screws at each end
Insert screwdriver here or here
3.2Press the vertical adjust tab toward the side of the base and lift out the board.
LED ON
3.3Select a mounting location. Mount the sensor where an intruder will most likely cross through the coverage pattern.
3.4Avoid:
3.5Observe the Pet Immunity mounting recommendations.
NOTE: The upper areas are not pet immune.
Mounting
Outdoors
Windows
and
Uninsulated
Walls
Direct Sunlight
Direct Hot or Cold Drafts
Moving Objects
NO |
| |
OK | Pet | |
Immune | ||
| ||
| Area |
7.5
(2.3 - 2.7 m)
Heat
Sources Air
Conditioning
Outlets
Mount the detector 7.5 to 9 feet |
|
(2.3 to 2.7 meters) above the floor | Don't point where pets can climb |