28 en Subsystem Monitoring | RAID Subsystem |
|
|
LED |
| Name | Color | Status |
|
|
|
|
|
1 |
| Ready | Green | FLASHING indicates controller initialization |
|
|
|
| is taking place. |
|
|
|
| ON indicates the controller is active and |
|
|
|
| operating properly. |
|
|
|
| OFF indicates the controller is not ready for |
|
|
|
| operation. |
|
|
|
|
|
2 |
| Hst Bsy | Green | FLASHING indicates there is activity on the |
|
| (Host Busy) |
| host ports. |
|
|
|
| OFF indicates there is no activity on the host |
|
|
|
| ports. |
|
|
|
|
|
3 |
| Drv Bsy | Green | FLASHING indicates there is activity on the |
|
| (Drive Busy) |
| drive ports. |
|
|
|
| OFF indicates there is no activity on the |
|
|
|
| drive ports. |
|
|
|
|
|
4 |
| C_Dirty | Amber | ON indicates that the cache memory is dirty |
|
| (Cache |
| or is being held up via the BBU during a sys- |
|
| Dirty) |
| tem power loss. |
|
|
|
|
|
5 |
| BBU Fail | Amber | ON indicates the BBU cannot sustain the |
|
|
|
| cache memory. This maybe caused by a |
|
|
|
| missing BBU. |
|
|
|
| OFF indicates the BBU is functioning nor- |
|
|
|
| mally and is able to sustain the cache mem- |
|
|
|
| ory. |
|
|
|
| FLASHING indicates the BBU is charging. |
|
|
|
| NOTE: This LED is only functional when a |
|
|
|
| BBU is installed in the subsystem. |
|
|
|
|
|
Table 4.4 | Controller Module LED Definitions |
|
F.01U.027.799 V2 2008.08 | Bosch Security System |