This view shows the interior layout of the EX36IP Camera assembly after the faceplate has been removed.

2.3Camera: Mounting and setup:

Select a suitable location that protects the camera from accidental damage, tampering and environmental conditions exceeding the specifications of the camera to be mounted.

CAUTION! Ensure the selected location is protected from falling

! objects, accidental contact with moving objects and unintentional interference from personnel. Follow all applicable building codes.

These mounting guidelines should be followed:

1.) Locate the bracket such that it cannot be easily interfered with, either intentionally or accidentally.

2.) Select a smooth, flat mounting surface to ensure proper sealing. The surface must also be capable of supporting the combined weight of the camera and mounting hardware under all expected conditions of vibration and temperature. Camera performs best mounted approximately 3m off the ground.

2.1) Camera housing mounting

Installations on drywall must use #8 screws and #8 drywall nylon plugs or a superior connection. The camera’s mounting holes are located on the left and right side of the housing. Refer to figure below. Depending on the type of mounting surface (brick, wood, etc.), it may be necessary to pre-drill these holes for the mounting screws. It is recommended that these holes be marked using the housing as a drill template and then drilled separately. This way no burrs or debris will fall into the housing. Ensure the power and video cables are not crimped or stressed after the camera has been mounted.

MAN36IPB Rev.0 2008.10

Quick Install

Bosch Security Systems

Page 8
Image 8
Bosch Appliances EX36-IP installation manual Camera Mounting and setup, These mounting guidelines should be followed