Bosch Appliances HBN 74 instruction manual CONNECTING TO 208 VOLT CIRCUIT, In Canada

Models: HBN 74

1 12
Download 12 pages 60.38 Kb
Page 10
Image 10
In Canada:

In Canada:

Wiring must conform to Canadian Electrical Code C22.1- latest edition.

You can obtain a copy of the Canadian Electrical Code by writing:

Canadian Standards Association 178 Rexdale Boulevard

Rexdale (Toronto), Ontario, Canada M9W 1R3

4.Wire size (COPPER WIRE ONLY) and connec- tions must be suitable for the rating of the appli- ance per the National Electrical Code require- ments. The flexible armored cable extending from the oven should be connected directly to the junc- tion box.

5.The junction box should be located so as to allow as much slack as possible between the junction box and the oven so it can be moved if servicing is ever required.

6.A U.L. listed conduit connector must be provided at each end of the power supply cable.

CONNECTING TO 208 VOLT CIRCUIT

This option is provided for areas where standard 240 Volt service is not available. This option must be accessed with the oven connected to power source, with the oven door (upper oven in double oven) open, and using the following sequence:

1.Touch CANCEL pad.

2.Turn rotary knob clockwise until you hear 6 double beeps.

3.Turn rotary knob counter-clockwise until you hear 9 double beeps.

4.Touch START pad.

5.Touch COOKING MODE pad; this sets oven to 208 Volts.

6.Touch START pad to save selection of 208 Volts.

PB

Page 10
Image 10
Bosch Appliances HBN 74 instruction manual CONNECTING TO 208 VOLT CIRCUIT, In Canada