16 MMD 540H Hybrid Multimeter Meter Functions

Meter Functions – Capacitance (CAP)

IMPORTANT: Turn the power OFF to the test circuit

ÑSelect the Capacitance “CAP” function with the rotary switch and mode button

Insert:

ÑBlack lead in COM terminal.

ÑRed lead in V-Ω-RPMterminal

CAUTION: When checking in- circuit capacitance, be sure that the circuit has all power removed and all capacitors are fully discharged.

Touch the test lead probes across the capacitance circuit to be tested. Read the measured value from the LCD display.

NOTE:

1. The bar graph is disabled in

capacitance measurement mode.Black–Red+ However, since the measurement

time of 4mF and 40mF modes is quite long (3.75s and 7.5s

respectively, to be precise), the bar graph is instead used to display the time required to accomplish the measurement.

2.In order to obtain an accurate reading, a capacitor must be discharged before measurement begins. The meter has a built- in discharge mode to automatically discharges the capacitor. In discharge mode, the LCD displays “DIS.C”

3.Discharging through the chip is quite slow. We recommend the user to discharge the capacitor with some other apparatus.